SPECIFICATION CONTROL DRAWING 44A122X TWO CONDUCTOR CABLE, SHIELDED, JACKETED, Date Revision TITLE 1-9-06 D GENERAL PURPOSE, 1000 VOLT This specification sheet forms a part of the latest issue of Raychem Specification 44. SHIELD - COPPER, COATING SAME AS ON CONDUCTOR EXCEPT TIN-COATED JACKET - RADIATION-CROSSLINKED, SHIELD WITH SILVER-COATED HIGH MODIFIED PVF 2 COMPONENT WIRE - 44A021X STRENGTH ALLOY CONDUCTOR TABLE I. CABLE CONSTRUCTION DETAILS JACKET OUTSIDE CONDUCTOR SHIELD MAXIMUM PART NUMBER SIZE THICKNESS DIAMETER SIZE WEIGHT 1/ (in.) (AWG) (AWG) (in.) (lb/1000 ft) MINIMUM NOMINAL NOMINAL MAXIMUM 44A122X-26-* 26 36 .006 .008 .118 .124 10.3 44A122X-24-* 24 36 .008 .130 .006 .136 12.9 44A122X-22-* 22 36 .006 .008 .146 .152 16.2 44A122X-20-* 20 36 .006 .008 .162 .169 20.7 44A122X-18-* 18 36 .009 .186 .007 .193 27.9 44A122X-16-* 16 36 .007 .009 .202 .210 33.4 44A122X-14-* 14 36 .009 .236 .007 .244 45.9 44A122X-12-* 12 36 .008 .010 .276 .286 64.3 44A122X-10-* 10 36 .008 .010 .334 .351 96.3 44A122X- 8-* 8 36 .012 .458 .010 .481 161. 44A122X- 6-* 6 34 .010 .012 .558 .586 247. 44A122X- 4-* 4 34 .015 .672 .013 .705 377. TABLE II. CABLE PERFORMANCE DETAILS BEND TESTING WEIGHT MANDREL DIAMETER (lb) ( 3%) (inch) ( 3%) PART NUMBER 1/ LIFE CYCLE, IMMERSION LIFE CYCLE, IMMERSION COLD COLD AND ACCELERATED AGING BEND AND ACCELERATED AGING BEND 44A122X-26-* 3.00 3.00 .375 3.00 6.00 .375 6.00 44A122X-24-* 6.00 44A122X-22-* 6.00 6.00 .375 6.00 44A122X-20-* 6.00 6.00 .500 9.00 44A122X-18-* 6.00 6.00 .500 9.00 44A122X-16-* 6.00 6.00 1.00 12.0 6.00 1.00 12.0 44A122X-14-* 6.00 44A122X-12-* 10.0 10.0 1.50 12.0 44A122X-10-* 10.0 10.0 2.00 12.0 44A122X- 8-* 18.0 18.0 3.00 15.0 44A122X- 6-* 18.0 18.0 3.00 24.0 18.0 3.00 24.0 44A122X- 4-* 18.0 NOTE: Nominal values are for information only. Nominal values are not requirements. Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. 1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER, AN ALTERNATIVE COLOR CODE MAY REPLACE MIL-STD-681 COLOR CODE DESIGNATORS. (EXAMPLE: 901/902... MAY BE REPLACED BY Axxx.) OTHER CODES AND SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER. R Wire & Cable DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL. 501 Oakside Avenue Redwood City, CA 94063-3800 Page 1 of 2 THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. Phone: 1-800-227-8816 REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. Fax: 1-650-361-6297 2006 Tyco Electronics Corporation. All rights reserved.Revision SCD Number Page 2 of 2 SPECIFICATION CONTROL DRAWING D 44A122X CABLE RATINGS AND ADDITIONAL REQUIREMENTS TEMPERATURE RATING: 150C Maximum continuous conductor temperature VOLTAGE RATING: 1000 volts (rms) at sea level ACCELERATED AGING: 300 3C for 6 hours BLOCKING: 150 3C for 6 hours DIELECTRIC WITHSTAND: 3000 volts (rms), 60 Hz, 1 minute FLAMMABILITY: 30 seconds (maximum) 3 in. (maximum) no flaming of facial tissue IMMERSION: Diameter increase 5% (maximum) no cracking, no dielectric breakdown JACKET COLOR: White preferred JACKET CONCENTRICITY: 70% (minimum) JACKET ELONGATION AND TENSILE STRENGTH: Elongation, 200% (minimum) Tensile Strength, 4000 lbf/in (minimum) JACKET FLAWS: Spark Test, 1.5 kV (rms) Impulse Dielectric Test, 6.0 kV (peak) LIFE CYCLE: 200 3C for 168 hours LOW TEMPERATURE-COLD BEND: -65 2C for 4 hours SHIELD COVERAGE: 85% (minimum) VOLTAGE WITHSTAND TEST (Post Environmental): 1000 volts (rms), 60 Hz, 1 minute PART NUMBER: The X in the part numbers on page 1 shall be replaced by the applicable conductor material designator as follows: 1 tin-coated copper 2 silver-coated copper 3 nickel-coated copper 4 silver-coated high strength copper alloy (AWG s 26-16 only) 6 nickel-coated high strength copper alloy (AWG s 26-20 only) The in the part numbers on page 1 shall be replaced by color code designators with a dash separating the component wire color from the jacket color. 1/ Example: AWG 20, tin-coated copper, black and brown component wires white jacket: 44A1221-20-0/1-9 1/ see footer section on page 1