Passive 1x/10x Voltage Probe P2220 P2221 Datasheet 1.5 m length UL3111-1, CSA1010.1, EN61010-1, EN61010-2-031, and IEC61010-2-031 Applications Relative low-frequency measurements Low-frequency computer and telecom measurements Power supplies Low-frequency amplifiers P2220 P2221 passive voltage probes The P2220 and P2221, 200 MHz passive voltage probes permit selection of 1x or 10x attenuation, using a switch located on the probe head. Tektronix passive probe solutions provide high reliability and testing accuracy for basic oscilloscope measurements. The P2220 and P2221 are The P2220 probe is compatible with TDS200, TDS1000, TDS1000B, compact passive probes with selectable 1X/10X attenuation designed for TDS2000, TDS2000B, and TPS2000 Series oscilloscopes. The P2220 use with selected Tektronix oscilloscopes. probe also provides floating measurement capability up to 30 V with RMS TPS2000 Series oscilloscopes only. (Note: Do not float with TDS2000, TDS2000B, TDS1000, TDS1000B, or TDS200 Series oscilloscopes.) The P2221 is compatible with MSO2000 and DPO2000 Series Key features oscilloscopes. 1x/10x attenuation 200 MHz bandwidth www.tek.com 1Datasheet Specifications All specifications are guaranteed unless noted otherwise. All specifications apply to all models unless noted otherwise. 10X 1x Bandwidth DC to 200 MHz DC to 6 MHz Probe length 1.5 m 1.5 m Attentuation ratio 10:1 1:1 Compensation range All oscilloscopes with 1 M input P2220 15 to 25 pF P2221 10 to 25 pF Input capacitance 17.0 pF 110 pF Input resistance 10 M 1 M Maximum input voltage 300 V Cat II 150 V Cat II 1 1 Maximum voltage between reference 30 V 30 V RMS RMS lead and earth ground Ordering Information P2220 Passive Probe, 1x/10x, 200 MHz Passive Voltage Probe Includes retractable hook tip (013-0107-xx), 6-inch ground lead (196-3466-xx), adjustment tool (003-1433-xx), marker band set 2 (016-1315-xx), instruction manual (071-1464-xx). P2221 Passive Probe, 1x/10x, 200 MHz Passive Voltage Probe for MSO/DPO2000 Series oscilloscopes Includes retractable hook tip (013-0107-xx), 6-inch ground lead (196-3466-xx), adjustment tool (003-1433-xx), marker band set 2 (016-1315-xx), instruction manual (071-2335-xx). 1 The float voltage must be subtracted from the tip to earth ground voltage. For example, if the reference lead is floated to 30 V while the probe is in the 10x position, the tip voltage to the reference lead is RMS limited to 270 V . RMS 2 The accessory quantities may differ when multiple probes are shipped with an oscilloscope/probe system. 2 www.tek.com