Series C60 Optically Isolated 0.5 to 2.5A Bi-directional Solid-State Relay Part Relay Number Description C60-X0 Solid State Relay, Terminals for Through Hole Mount SC60-X0 Solid State Relay, Terminals for Surface Mount Add suffi c 01 to denote 60Sn/40Pb Pre-Tinned Leads ELECTRICAL SPECIFICATIONS (25C UNLESS OTHERWISE SPECIFIED) INPUT (CONTROL) SPECIFICATIONS (SEE NOTE 1) FEATURES/BENEFITS Parameters Min Typ Max Units Power FET Output with Very Low On Resistance: Virtually no off set with very low Input Voltage Drop (See Fig 1) 1.1 1.5 Vdc leakage and voltage drop. Input Current 10 50 mA Optical Isolation: Isolates control elements (See Fig 1 and Notes 1, 7) from load transients. Eliminates ground Input Current (Guaranteed On), 10 mA loops and signal ground noise. Three Terminal Output: Output FETs can (See Fig 4 and Note 7) be paralleled externally to change current Input Current (Guaranteed Off) 100 A load rating. Reverse Voltage Protection -6 Vdc Floating Output: Allows for high and low side switching. OUTPUT (LOAD) SPECIFICATIONS Switches High Voltages and Currents: Part Number DC Bi-Directional Voltages to 400 Vdc. Current to 2.5 Adc. Bi-directional, DC or AC. Parameter Min Max Min Max Units High Noise Immunity: Control circuit Output Voltage C60-10 60 60 Vdc Rating C60-20 100 100 Vdc cannot be triggered by output switching C60-30 200 200 Vdc noise. C60-40 400 400 Vdc 6-Pin Mini-DIP Package: Standard or surface mount available. Output Current C60-10 2.5 1.25 Adc Rating C60-20 1.5 0.75 Adc C60-30 1.0 0.5 Adc DESCRIPTION C60-40 0.5 0.25 Adc The Series C600 solid-state relay is an On Resistance C60-10 0.07 0.28 Ohm advanced design capable of switching very (See Note 6) C60-20 0.2 0.7 Ohm C60-30 0.45 1.8 Ohm heavy loads in a physically small 6-pin mini C60-40 1.0 4.0 Ohm DIP package. These relays have a power FET output that ensures low On resistance, no Leakage Current at Rated Voltage 2.0 1.0 Adc off set voltage and low leakage current. They Turn-On Time C60-10 4.0 4.0 ms 10mA C60-20, -30, -40 3.0 3.0 ms are versatile and can be used to switch AC, Bi-directional or DC loads. Optical isolation Turn-Off Time C60-10 4.0 4.0 ms C60-20, -30, -40 3.0 3.0 ms ensures complete protection of signal lines, power and ground bus and control circuits Output C60-10 1000 500 pf Capacitance C60-20 500 250 pf from switching noise and EMI. C60-30 400 200 pf C60-40 400 200 pf 9 9 Isolation (Input to Output) 10 10 Ohms SCHEMATIC Dielectric Strength 1500 1500 Vrms Capacitance (Input to Output) 3.0 3.0 pf Junction Temperature (T ) 125 125 C J Junction to Case Thermal Resistance 25 C Case to Ambient Thermal Resistance 75 C/W Moisture Sensitivity Level (MSL) 6 2018 TELEDYNE RELAYS (800) 284-7007 www.teledynerelays.com C60-X0 REV ASeries C60 Optically Isolated 0.5 to 2.5A Bi-directional Solid-State Relay CHARACTERISTIC CURVES C600-10 C600-20 C600-30 C600-40 C600-10 C600-20 C600-30 C600 C600-40 C600 MECHANICAL SPECIFICATION WIRING CONFIGURATION NOTES: 1. Series resistor is required to limit input current to 50 mA maximum. 2. The input current is 10 mA for all tests unless otherwise specifi ed. 3. The surge current is non-repetitive for a maximum duration of 20 ms (See Figure 3). 4. Loads may be connected to positive or negative referenced power supplies. Inductive loads must be diode suppressed. 5. Continuous load current is rated under the conditions of still air and mounted on a printed circuit board. LEAD MATERIALS = COPPER 6. To calculate ON Resistance for a given junction LEAD FINISH = NICKEL PALLADIUM PLATING WITH GOLD FLASH temperature calculate the new ROn using the equation shown below: ROn=R(25C)x e0.006(TJ-25C) 7. Turn on Time can be controlled with input control current. Calculate a new turn-on time: tOn=(tSpecifi cation Limit (10mA/IIn) 8. Load voltage rating should be derated 10% at -40C 9. Pin 3 is internally connected to pin 2. 10. Part does not contain pure tin C60-X0 REV A SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE 2018 TELEDYNE RELAYS