Management Interface
Highlights
Single phase 30A 120V Auto
The management interface for this PDU model is transitioning to a new technology platform. The new interface
Transfer Switch / ATS PDU;
can be distinguished by a USB-A port (for EnviroSense2 modules) in place of the round ENVIROSENSE port.
Highly reliable Solid State
For managing the units containing the round port, Tripp Lite recommends using the PowerAlert Console
Switching
Launcher rather than a web browser. This application enables local access of the PDU using a self-contained,
Enables redundant A/B power
compatible Java Runtime Environment version. The Console Launcher can be downloaded for free; click the
option for single-corded network
above link or go to the Management Solutions / Utilities page. Units with the new interface work will with most
devices
current web browsers.
Separate primary & secondary
inputs connect to any two
2.9kW Single-Phase ATS / Switched PDU, 120V
compatible power sources
Outlets (24 5-15/20R, 1 L5-30R) 2 L5-30P, 2 10ft
2U rackmount, 2 L5-30P inputs,
Cords, 2U Rack-Mount, TAA
25 switched outlets (24 5-15/20R,
1 L5-30R)
MODEL NUMBER: PDUMH30ATNET
Individually switched outlets and
built-in network interface enables
remote control and monitoring
Digital meter reports voltage, kW
load level and output amperage
in 4 load segments
TAA Compliant
Package Includes
ATS / Switched PDU with two
L5-30P inputs
Installable 2U mounting brackets
Operating manual
Description
Tripp Lite Switched ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate
connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input
cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is
restored and stable. Highly reliable solid-state switching between primary and secondary inputs occurs in 1-5 milliseconds. Switched PDU features include
individually controllable output receptacles and built-in network interface. Super-fast switchover between primary and secondary power sources occurs within
milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant
power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when
each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with
zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing
separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power
quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's
display primary or secondary power availability.
Features
120V 30A Power Distribution Unit (PDU) with Auto-Transfer Switch (ATS) and Switched outlets (Agency de-rated to 24A)
1 / 4
ATS features provide redundant power for critical network equipment with a single input power cord
Switched PDU features enable programmable or real-time power control of individual outlets via built-in network interface
Visual meter reports output amp and kW power consumption, plus voltage and temperature/humidity data with optional ENVIROSENSE sensor
25 switched outlets (24 5-15/20R & 1 L5-30R)
2U horizontal rackmount form factor; 11.9 in. / 30.2cm depth
Set of two 10 ft. / 3m NEMA L5-30P input line cords enable separate PRIMARY and SECONDARY input connections
ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails or becomes unstable, the ATS will switch to
maintain output sourced from the secondary input cable until power on the primary input is restored and stable
Highly reliable solid-state switching enables fast 1-5 millisecond trasfer between primary and secondary inputs
ATS configurations enable fault-tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord
is connected to a separate UPS system (in a two-UPS environment, the primary input cable must be supported by an online UPS with zero transfer time
similar to Tripp Lite SmartOnline series)
Advanced ATS configurations utilizing separate mains circuits, backup generators and even separate out of phase utility power grid feeds are fully
supported
On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source when unavailable or of lower
quality than the primary source
DHCP/Manual configuration support; Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet,
SSH, FTP, DHCP, BOOTP, NTP protocols
Compatible with optional ENVIROSENSE temperature monitor
Outlets are factory programmed for sequential turn-on at 250 millisecond intervals as the PDU is first energized
Front panel LEDs confirm power availability on both input lines
Compliant with the Federal Trade Agreements Act(TAA) for GSA Schedule purchases
Specifications
OVERVIEW
PDU Type Auto-Transfer Switch; Switched
OUTPUT
3.05kW (127V), 2.88kW (120V), 2.4kW (100V) / 30A total capacity (Agency de-rated 24A); 24A max per L5-30R
Output Capacity Details
outlet; 20A max per breakered load bank; 16A max per 5-15/20R outlet
Frequency Compatibility 60 Hz
Output Receptacles (24) 5-15/20R; (1) L5-30R
Output Nominal Voltage 100; 120; 127
Overload Protection Two 20A output breakers protect 12 5-15/20R outlets each
Customized Load Management
25 individually controllable outlets
Receptacles
INPUT
PDU Input Voltage 100; 120; 127
Recommended Electrical Service 30A 120V
2 / 4