3 Very High Power Density: 15.27W/in Class I or Class II Configuration UL/EN60601-1 Medical Approval Small 2x3 package Efficiencies up to 91% Suitable for BF Applied Part Applications Meets Efficiency Level VI Requirements No load power consumption <300mW Electrical Specifications Input Environmental 3 1 Operating Temperature -30C to +70C Input Voltage 90-264VAC Storage Temperature -30C to +85C Input Frequency 47-63 Hz Humidity 20% - 90% RH Input Current (RMS) 2A max. 115VAC Operating altitude <5,000m 1A max. 230VAC MTBF: >250K hours per MIL-HDBK-217F at full load Inrush Current 45A max 115VAC and 25C ambient 90A max 230VAC No Load Power Consumption <300mW Power Factor >0.9 240VDC and 120VDC Safety & EMC Safety Output Approvals Total Output Power 120W with 10CFM Forced Air USA/Canada UL60601-1 3.1 Edition, 2 100W Convection Only UL62368-1 (Pending) rd Output Voltage See models and ratings table. Europe IEC/EN 60601-1 3 Edition, CB Report, Hold Up Time 10mS minimum EN62368-1 (Pending) Efficiency Up to 91%. See models and ratings table. Line Regulation 1% Isolation 5 Voltage Adjustability 4% 4000VAC / 5656VDC (2 x MOPP) Input to Output 5 Setpoint accuracy 2% Input to Ground 2000VAC / 2828VDC (1 x MOPP) 5 Minimum Load No Minimum Load Output to Ground 1500VAC / 2121VDC (1 x MOPP) <100A at 264Vac Touch Current Protection Features EMC (IEC60601-1-2:2014): EN55011 Class B Emissions Overvoltage Latch off. EN55011 Class B (Class I) Conducted Overtemperature Latch off. EN55011 Class A (Class II) Radiated Overcurrent Hiccup Mode. OCP Threshold typically IEC/EN60601-1-2: 2007 Susceptibility 150%. IEC 61000-3-2: Class A Harmonic Currents Short Circuit Hiccup Mode. IEC 61000-3-3 Voltage Flicker IEC 61000-4-2: 15kV Air, 8kV contact Electrostatic Discharge IEC 61000-4-3: 10V/m Radiated Immunity Notes IEC 61000-4-4: +/-2kV EFT/Burst IEC 61000-4-5: 2005 1kV diff, 2kV com Surge Immunity 1. Derate output power by 0.8%/V below 115VAC IEC 61000-4-6: 10Vrms Conducted Immunity 2. Derate convection only output power by 10% for U-Channel models. IEC 61000-4-8: 30A/m Magnetic Field Derate convection only output power by 15% for Enclosed models. IEC 61000-4-11: 30% reduction for 500ms, Dips / Interruptions 3. See derating curves on the second page for operation above 50C 100% reduction for 10ms. 4. Dimensions given are those of PCB. I/O conductors extend slightly Physical beyond PCB edge. 5. Testing isolation with an AC generator is not recommended. Either Dimensions 3 .04L x 2W x 1 .3 1 H Typical perform isolation testing with a DC voltage, or consult with our Weight 6.4oz Typical engineering staff for AC test considerations. Your Partners in Power ... Power Partners, Inc. 43 Broad Street Hudson, MA 01749 Tel: (978)567-9600 Fax: (978)567-9601 Specifications subject to change. PDAM120: February 20, 2019 Website: www.powerpartners-inc.com Medical AC/DC Power Models and Ratings 6 Model Number Output Maximum Maximum Output Ripple & Max Typical 7 Voltage Load with Load with Load Noise (Vp-p) Capacitive Efficiency Convection 10CFM Regulation Load at 230VAC 2 Cooling Forced Air (F) PDAM120-12A 12V 8.333A 10.000A +/-1% 160mV 3000 90% PDAM120-14A 24V 4.167A 5.000A +/-1% 240mV 1500 90% PDAM120-18A 48V 2.083A 2.500A +/-1% 480mV 500 91% PDAM120-12B 12V 7.500A 10.000A +/-1% 160mV 3000 90% PDAM120-14B 24V 3.750A 5.000A +/-1% 240mV 1500 90% PDAM120-18B 48V 1.875A 2.500A +/-1% 480mV 500 91% PDAM120-12C 12V 7.083A 10.000A +/-1% 160mV 3000 90% PDAM120-14C 24V 3.541A 5.000A +/-1% 240mV 1500 90% PDAM120-18C 48V 1.770A 2.500A +/-1% 480mV 500 91% Notes (continued from first page): 6. Model number ending with A indicates open frame format. Model number ending with B indicates U-channel format. Model number ending with C indicates enclosed format. 7. Measured at 20MHz bandwidth with a 47uF electrolytic and 0.1uF ceramic capacitor in parallel with the DC output rails. 8. Input voltage derating and thermal derating are superimposed. The PDAM120 cannot operate with input voltages below 99VAC in thermal environments below 10C 8 Derating Curves Your Partners in Power ... Power Partners, Inc. 43 Broad Street Hudson, MA 01749 Tel: (978)567-9600 Fax: (978)567-9601 Specifications subject to change. PDAM120: February 20, 2019 Website: www.powerpartners-inc.com Medical AC/DC Power