TECHNICAL BULLETIN TB-7510 VACUUM CLEANER AND BLOWER Made in Britain Installation, Operation and Maintenance The appliance is constructed to Operating instructions safety class II: Double insulated 1. Push hose end into design in compliance with CE suction opening standards. 2. Press the suction nozzle onto - Durable and compact design the free suction hose-end - Motor has thermal protection 3. Place rocker switch in off with RFI/EMC filter position - Hose assembly extends to 4. Set electronic control to 130cm medium power ( 231700, - Includes hard crevice and soft 231710) rubber nozzle 5. Insert the plug into the - 1.2 l filter bag electrical supply and start - Advanced 5 stage filtration appliance, pressing on-off Figure 1. 231700 Vacuum system switch too position. Cleaner. - 3m long power cord - Conductive carry strap Description Compact lightweight blower / Inspection vacuum cleaner designed for precise removal and collection of Remove the vacuum cleaner from the carton and inspect for dry dust particles and debris from electrostatic static sensitive shipping damages. devices (ESDS). The conductive nozzles drain-off any static build- Each unit should include the following: up to earth. In order to comply with EN61340- 1 Vacuum Cleaner (231700 or 231710) 5 recommendations for working in an ESD protected area (EPA), the 1 1.3m Hose Figure 2. 231700 Vacuum appliance housing, nozzles, hose, 2 Nozzles Cleaner. 1 Carrying Strap shoulder strap, cable and accessories are fully conductive. If there is substantial loss of Optional Accessories: The vacuum cleaner can retain vacuum or blow-pressure, take dust and fine dry particles as - 231725: Replacement Bags, the following steps: Pack of 10 small as 0,3 micron, the vacuum 6. Remove appliance from cleaner is fitted with a double- - 231705: Carry Bag the EPA layer paper filter bag and an 7. Check whether nozzle or electro-static charged micro- suction-hose have become motor filter. blocked The appliance can also be 8. Switch off appliance and converted in seconds into a disconnect plug from powerful blower for dust removal electrical supply in area s otherwise not accessible 9. Lift metal bottom lock and - the blower s air-current is cfc- remove housing s front cover free and contains no oil or water 10. Remove and replace the residue. spent paper filter bag 11. Replace electrostatic micro- motor filter. UNIT C, 4TH DIMENSION, FOURTH AVENUE, LETCHWORTH, HERTS, SG6 2TD UK Phone: 0044 (0) 1462 672005, Fax: 0044 (0) 1462 670440 e-mail: Service Vermason.co.uk, Internet: Vermason.co.uk TB-7510 December 2008 Page 1 of 2 2008 VermasonDo not operate the vacuum Note: This appliance is equipped Limited Warranty cleaner near flammable or with a thermal protection device. Vermason expressly warrants that for a period combustible liquids or fumes, do To protect the motor from of one (1) year from the date of purchase, overheating, it will switch off not collect anything that is hot, Vermason Vacuum Cleaners will be free of defects in material (parts) and workmanship smoking or burning with the automatically if there is an (labour). Within the warranty period, a unit will inadequate air supply. To enable a cleaner. Do not pick-up burning be tested, repaired or replaced at Vermasons cigarettes, hot ashes or matches. restart, check filters, bags, nozzle option, free of charge. Call Customer Service Use safety glasses when the and hose for blockages. On the at 0044 (0) 1462 672005 for a Return Material Authorisation (RMA) and for proper shipping application is in blow mode, never 231700, 231710 version, reduce instructions and address. Any unit under blow in corners or in the direction the power setting. When the warranty should be shipped prepaid to the of sharp objects such as staples, motor has cooled down, the Vermason factory. You should include a copy paperclips, drawing-pins, needles, appliance should restart after 15- of your original packing slip, invoice, or other pins and glass fragments. proof of purchase date. Warranty repairs will 20 minutes. take approximately two weeks. Never use the appliance without Safety points the filter bag and motor filter in If your unit is out of warranty, Vermason will quote repair charges necessary to bring your place. When cleaning this equipment, unit to factory standards. Call Customer Never re-use spent filter bags. ensure it is switched-off and no Service at 0044 (0) 1462 672005 for a Return longer connected to the power Material Authorisation (RMA) and proper supply. shipping instructions and address. Ensure any object to be cleaned, Warranty Exclusions is itself connected to earth in THE FOREGOING EXPRESS WARRANTY IS accordance with EN 61340-5 MADE IN LIEU OF ALL OTHER PRODUCT recommendations. WARRANTIES, EXPRESSED AND IMPLIED, INCLUDING MERCHANTABILITY AND Always use the on-off rocker FITNESS FOR A PARTICULAR PURPOSE switch to turn the appliance on or WHICH ARE SPECIFICALLY DISCLAIMED. off. The express warranty will not apply to defects This appliance is made for indoor or damage due to accidents, neglect, misuse, alterations, operator error, or failure to properly use only, it must be stored in a maintain, clean or repair products. dry place and should not be Limit of liability operated under wet conditions In no event will Vermason or any seller be such as wet floors or wet responsible or liable for any injury, loss or surfaces. Never touch the damage, direct or consequential, arising out of appliance or the plug with wet the use of or the inability to use the product. hands. Before using, users shall determine the This appliance is not designed, suitability of the product for their intended use, and users assume all risk and liability nor suitable, to collect liquids, nor whatsoever in connection therewith. health endangering dust such as asbestos or tropical wood sawdust. Unplug the appliance when it is not in use Do not pull the cord to unplug it, do not use the cord to carry or pull the appliance, keep the cord away from hot surfaces. Never use the appliance if the cord or plug are damaged Never use the appliance if the suction is blocked or with completely restricted vacuum flow or air exit. UNIT C, 4TH DIMENSION, FOURTH AVENUE, LETCHWORTH, HERTS, SG6 2TD UK Phone: 0044 (0) 1462 672005, Fax: 0044 (0) 1462 670440 e-mail: Service Vermason.co.uk, Internet: Vermason.co.uk TB-7510 Page 2 of 2 2008 Vermason