Data sheet Weidmller Interface GmbH & Co. KG ConnectPower Klingenbergstrae 16 CP DC UPS 24V 40A D-32758 Detmold Germany Fon: +49 5231 1429-0 Fax: +49 5231 14292083 www.weidmueller.com The UPS control unit together with the associated battery module and the power supply unit form a complete DC UPS system. In normal operation, the input voltage from the UPS control unit is connected directly to the load. In the event of a mains failure (drop of the DC input voltage) the system switches instantly to battery operation. Once the mains supply has been restored, the system switches back to normal operation and the battery is fully recharged by the integrated charger. Three relay outputs, as well as three additional active transistor outputs and a control input to lock battery operation, provide full remote control by means of SPS or DCS control. Numerous modes of operation and an easy- to-use status display provide rapid fault diagnosis and optimum customisation to the application. General ordering data Type CP DC UPS 24V 40A Order No. 1370040010 Version UPS control unit GTIN (EAN) 4050118202342 Qty. 1 pc(s). Creation date February 20, 2017 5:29:44 AM CET Catalogue status 10.02.2017 / We reserve the right to make technical changes. 1Data sheet Weidmller Interface GmbH & Co. KG ConnectPower Klingenbergstrae 16 CP DC UPS 24V 40A D-32758 Detmold Germany Fon: +49 5231 1429-0 Fax: +49 5231 14292083 www.weidmueller.com Technical data Dimensions and weights Width 66 mm Width (inches) 2.598 inch Height 130 mm Height (inches) 5.118 inch Depth 150 mm Depth (inches) 5.905 inch Net weight 1,051.8 Kg Temperatures Humidity 5...95 %, no condensation Operating temperature -25 C...70 C Storage temperature -40 C...85 C Battery module Parallel connection option yes, max 2. Rated voltage 24 V Storage medium 3.4 Ah, 7.2 Ah, 12 Ah, 17 Ah, Selectable with rotary switch Integrated battery charger Battery availability test every minute Charging current 0.15 CA Charging feature Charging voltage (temperature IU characteristic curve compensated) 27, 48 V 20C Temperature coefficient - 48 mV / C Operating interfaces and control inputs DIP switch Inversion of transistor Remote disconnection (Interlock) outputs, Operation without temperature probe Yes Selector switch battery Selector switch buffer times 0.5 min, 1 min, 3 min, 5 3.4 Ah, 7.2 Ah, 12 Ah, 17 min, 10 min, 20 min, 30 Ah, No Battery, Service min, 45 min, , w/0 Temperature probe NTC 100 k Input DC current consumption max. 200 mA (without DC input voltage range battery), max. 0.5 A (with fully charged battery) 20...30 V DC Input current 43 A Input fuse (internal) Yes Max. approved input current 52 A Wire connection method Screw connection output Continuous output current U 48 A 45 C, 24 A 70 Output current, max. Rated C, 40 A 60 C 48 A Output voltage Vo = Vin - 0.2 V normal Overload protection operation (Imax), Vo = Vin - 0.3 V battery operation (Imax) Yes Parallel connection option yes, max 2., Yes, with Power boost U Rated diode module 48 A for 1 min, ED = 5 % Protection against inverse voltage Rated (nominal) output current U Yes 40 A 60 C Nom Rated output voltage Residual ripple, breaking spikes < 50 mV 24 V DC, I 24 V DC 1 % SS N Temperature coefficient - 48 mV / C Temperature probe NTC 100 k Wire connection method Screw connection Creation date February 20, 2017 5:29:44 AM CET Catalogue status 10.02.2017 / We reserve the right to make technical changes. 2