AC-DC Power Supplies XPPower VES120 Series 120 Watts Energy Efficiency Level VI European CoC Tier 2 High Power Density Single Outputs from 12 V to 24 V <0.15 W Standby Power China Compulsory Certification (CCC) Qualified 0 C to 60 C Operation BRAND Optional Output Connector Low Cost Dimensions: VES120: 6.61 x 2.80 x 1.48 (168.0 x 71.0 x 37.5 mm) Models & Ratings (1) Output Power Output Voltage Output Current Total Regulation Efficiency Model Number 12.0 V 10.00 A 89% VES120PS12 (2) 120 W 19.0 V 6.32 A 5% 89% VES120PS19 (2) 24.0 V 5.00 A 89% VES120PS24 Notes 1. Typical average of efficiencies measured at 25%, 50%, 75% and 100% load and 230 VAC input. 2. For optional Barrel Jack Connector, 2.5 mm inner positive, 5.5 mm outer negative, 11 mm length add suffix -B e.g. VES120PS24-B. Mechanical Details 47.240.79 (120020) 6.61 (168.0) 2.760.20 (705) Pin Function 1 Output + 2 Output + 19V & 24V: UL 10748 16AWG*1C+S Black 3 Return 12V: UL 10748 14AWG*1C+S Black 4 Return Connected to output Shell 4 PINS DC POWER CONNECTOR return and input ground 1 3 For optional barrel jack connector, 2 4 outer sleeve (negative) is connected to input ground 2.360.79 4.720.79 2.360.79 1.480.02 (6020) (12020) (6020) (37.50.5) IEC320-C14 CORE: 14.2*2*7.0*L28.5 Notes 1. All dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except 3. Weight: 1.27 lbs (580 g) approx. output cable length. 2. Output connector: Power Mini DIN, mates with Kycon KPJ-4S or equivalent. www.xppower.com 1 2.800.04 (71.01)AC-DC Power Supplies XPPower VES120 Series Input Characteristic Minimum Typical Maximum Units Notes & Conditions Input Voltage 90 264 VAC Input Frequency 47 63 Hz Input Current 2/1 A Measured at 115/230 VAC Inrush Current 130 A 230 VAC, cold start at 25 C Power Factor EN61000-3-2 Class A Earth Leakage Current 500 A 264 VAC, 60 Hz No Load Input Power 0.15 W Input Protection T3.15A/250 VAC internal fuse in line Output Characteristic Min. Typ. Max. Units Notes & Conditions Output Voltage 12 24 VDC See Models and Ratings table Initial Set Accuracy 2 % At 50% load Minimum Load No minimum load required Start Up Delay 3 s Start Up Rise Time 50 ms Hold Up Time 8 ms Full load and 115 VAC Line Regulation 0.5 % Total Regulation 5 % Maximum deviation, recovering to less than 1% within Transient Response 10 % 500 s for 50% step load 2% for 12 V, 1% for 19 & 24 V, Ripple and Noise 2/1 % pk-pk 20 MHz bandwidth, measured with 20 MHz Bandwidth and 10 F electrolytic in parallel with 0.1 F ceramic capacitor. Overshoot 2 % At turn on / turn off Overload Protection 120 200 % Overvoltage Protection 180 % Recycle mains to reset Short Circuit Protection Trip and restart (hiccup), auto resetting Temperature Coefficient 0.04 %/C Environmental Characteristic Minimum Typical Maximum Units Notes & Conditions Operating Temperature 0 +60 C Derate from 100% load at 40 C to 50% load at 60 C Cooling Natural convection Operating Humidity 10 90 %RH Non-condensing Storage Temperature -40 +70 C Operating Altitude 5000 m Shock IEC68-2-27, 30 g, 30 ms half sine, 3 times in each of 6 axes Vibration IEC68-2-6, 10-300 Hz, 2 g 15 mins/sweep, 60 mins for each of 3 axes, non operating Derating Curve 100% 80% 60% 40% 20% 0 20 40 60 Ambient Temperature (C) www.xppower.com 2 Output Power (%)