STAIRCASE LIGHTING TIMER ASM-10 INSTRUCTION MANUAL Zakad Mechaniki i Elektroniki ZAMEL sp.j. J.W. Dzida, K. odziska ul. Zielona 27, 43-200 Pszczyna, Poland Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04 www.zamel.pl, e-mail: marketing zamel.pl DESCRIPTION TECHNICAL PARAMETERS ASM - 10 The staircase lighting time delay Supply cables: L (black), N (blue) switch ASM-10 is used to control lighting Variable voltage supply: 230 V~ devices on staircases and corridors. Supply voltage tolerance: from -15 to +10 % After releasing the system it switches Nominal frequency: 50 / 60 Hz on the lighting with fluent brightening. The lighting is switched on by t time Variable power consumption: 41 mA 2 and followed by fluent blanking. The Power supply indicator: LED green system is equipped with intelligent anti Dim up time setting (t ): from 0 to 10 s (rotary potentiometer) 1 blocking function where you can preset Operating time setting (t ): from 0 to 10 min (rotary potentiometer) 2 the lighting blanking level in cases the Dim down time setting (t ): from 0 to 60 s (rotary potentiometer) 3 pushbutton is blocked. Lighting level adjustment when blocking is switched on (L): 10 100 % Receiver power supply indicator: dioda LED red Charging power: 30 600 W FEATURES Controlling element: triac 600 VA (clamps N, ) Number of switch cables: 11 2 Intelligent lighting control, Diameter of connecting cables: from 0,2 to 2,50 mm o Operating temperature: from -20 to +45 C lighting time adjustment, Operating position: freely switch on time adjustment, Assembly: rail TH35 (PN-EN 60715) Protection level of casing: IP20 (PN-EN 60529) blanking time adjustment, Protection level: II lighting level adjustment in cases the Over voltage category: II pushbutton is blocked, Pollution: 2 Electric strength: 1 kV (PN-EN 61000-4-5) input rated indicator, Dimensions (height / width / depth): doublemodule (35 mm) 90x35x66 mm doublemodule casing, Weight: 130 g Compatible with standards: PN-EN 60669-1 PN-EN 60669-2-1 TH-35 DIN rail installation. PN-EN 61000-4-2,3,4,5,6,11 The device is desig- APPEARANCE ned for one-phase in- stallation and must be supply voltage terminal (L) input terminals of the installed in accordance release system with standards valid in a particular country. The supply voltage terminal (N) CAUTION device should be con- nected according to the details included in this operating manual. Installation, connection and control should be car- r i e d o u t by a q u a l i fi e d e l e c t r i c i a n s t a f f, relay indicator light supply indicator light who act in accordance with the service manual and the device functions. Disas- sembling of the device is equal with a loss of guarantee and can cause electric dim up time adjusting operating time adjusting shock. Before installation make sure the range (t ) range (t ) 1 2 connection cables are not under voltage. The cruciform head screwdriver 3,5 mm should be used to instal the device. Im- proper transport, storage, and use of the light intensity adjusting dim down time d ev i c e i n fl u e n c e i t s w r o n g f u n c t i o n i n g . I t adjusting range (t ) range (L) 3 is not advisable to instal the device in the following cases: if any device part is missing or the device is damaged or de- formed. In case of improper functioning output clamps (N, ) of the device contact the producer. ver. 0.4.2 2006.06.19 13:00MOUNTING, FUNCTIONING CONNECTING TIME COURSE 1. Switch off the phase fuse, on which the installation is made, 2. Check the phase cable if there is no voltage, 3. Install device ASM-10 in distribution board on a rail TH-35, 4. Combine cables with clamps in accor- dance with installing scheme, 5. Switch on the voltage, 6. Use the potentiometer to adjust the time Tin, Tout, Ton as well as light in- tensity. The system, after switching on, turns on efl xibly the light. The time in which the device is operating, can be ufl ently adju- sted by means of potentiometer Tin, in the range of 0 to 10 seconds. Next the system sustains the lighting as long as it was adju- sted by the potentiometer Ton, in the range of 0 - 10 minutes. Finally, the system turns INNER DIAGRAM off the light in time Tout adjusted by the po- tentiometer in range of 0 60 seconds. The lighting is turned off totally, after passing of L N that time. The release of the system during realization of switching off function causes N RELAY CAPACITY IN the system turns on again. By the use of IN potentiometer L, it is possible to estima- te the level of lighting when the switch is IN C blocked (anti-block function). That level 4x can be adjusted in range of 10% to 100% - max. power of the electric bulb. DIMENSIONS EXAMPLE OF INSTALLATION 67,5 45,0 35,4 L N L / N 35,3 2,0 90,0 15,0 15,0 PRODUCT FAMILY The stairs automat ASM-10 belongs to fa- mily of staircase automats ASx. ASx - xx (/24V) Version 24 V AC/DC Wersja urzdzenia: 01 - 3, 4 wire installation 02 - anti-lock system 10 - dimmer function (double modular casing) Typical application: Type of casing: M - monomodular Staircase automat with a dimmer that works with 4 wire system controls N - surface mounting H - hermetical the lighting on the staircases. Pushes (illuminated) can be connected parallely. Symbol GUARANTEE CARD There is 24 months guarantee on the product 1. ZAMEL provides a two-year warranty for its products. 2. The ZAMEL warranty does not cover: a) mechanical defects resulting from transport, loading / unloading or other circumstances, b) defects resulting from incorrect installation or operation of ZAMEL products, c) defects resulting from any changes made by CUSTOMERS or third parties, to products sold or equipment necessary for the correct operation of products sold, d) defects resulting from force majeure or other aleatory events for which ZAMEL is not liable. 3. All complaints in relation to the warranty must be provided by the CUSTOMER in writing to the retailer after discovering a defect. 4. ZAMEL will review complaints in accordance with existing regulations. 5. The way a complaint is settled, e.g. replacement of the product, repair or refund, is left to the discretion of ZAMEL. Salesman stamp and signature, date of sale ver. 0.4.2 2006.06.19 13:00 66,0 60,0 35,5 16,0 16,8 6,2 ...