BISTABLE RELAY PBM-02 INSTRUCTION MANUAL Zakad Mechaniki i Elektroniki ZAMEL sp.j. J.W. Dzida, K. odziska ul. Zielona 27, 43-200 Pszczyna, Poland Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04 www.zamel.pl, e-mail: marketing zamel.pl DESCRIPTION TECHNICAL PARAMETERS The bistable relay PBM-02 is used to PBM - 02 control lighting or other devices by means Input (supply) terminals : L, N of monomodular pushbuttons connected Input rated voltage: 230 V~ in a parallel way. Pushing any button cau- Input voltage tolerance: from -15 to +10 % ses switching on or switching off the de- Nominal frequency: 50 / 60 Hz vices connected to output terminals. The Rated power consumption: 24 mA controlling impulse can be L or N line sig- Supply voltage control indicator: LED green nal. The Set and Rest control inputs allow Release terminals: IN, IN, IN central control of a relay group. Using the Release control current: 930 A inner relay memory allows to remember its current mode in cases of power supply Central control terminals: Set, Reset loss. Power/relay supply indicator: LED red Relay operating indicator: TEST button Output relay parameters: 1NO - 16 A / 250 V AC1 4000 VA FEATURES Number of terminal clamps: 10 2 Section of connecting cables: from 0,2 to 2,50 mm Bistable lighting control, o Ambient temperature range: from -20 to +45 C input rated indicator LED green, Operating position: free relay mode indicator LED red, Mounting: TH35 rail (PN-EN 60715) central control function, Protection degree: IP20 (PN-EN 60529) relay mode memory, Protection class: II system releasing from the L or N Overvoltage category: II cable, cooperation with monostable pus- Pollution degree: 2 hbuttons equipped with illumination Rated impulse withstand voltage: 1 kV (PN-EN 61000-4-5) lamps, Dimensions (height / width / depth): monomodular (17,5 mm) 90x17,5x66 mm TEST function, Weight: 80 g double-wire controll installation, Reference standards: PN-EN 60669-1 PN-EN 60669-2-1 voltage relay output - one NO (norma PN-EN 61000-4-2,3,4,5,6,11 closed) contact max 16 A capacity. The device is desig- APPEARANCE ned for one-phase in- stallation and must be Input supply terminals (L) Input supply terminals (N) installed in accordance with standards valid in CAUTION a particular country. Release terminals The device should be (IN, IN, IN) connected according to the details inclu- ded in this operating manual. Installation, connection and control should be carried Supply voltage control indicator out by a qualified electrician staff, who act in accordance with the service manual Power/relay supply indicator and the device functions. Disassembling of the device is equal with a loss of gua- Relay test rantee and can cause electric shock. Be- fore installation make sure the connec- tion cables are not under voltage. The cruciform head screwdriver 3,5 mm sho- uld be used to instal the device.Improper transport, storage, and use of the device influence its wrong functioning. It is not Central control terminals (S, R) advisable to instal the device in the follo- wing cases: if any device part is missing or the device is damaged or deformed. In Output (load) relay case of improper functioning of the devi- terminals (11, 11, 14) ce contact the producer. ver. 0.4.2 2006.06.26 08:00MOUNTING, FUNCTIONING CONNECTING bISTablE rElay 1, 2 ... N CENTRAL CENTRAL 1. Disconnect the power supply from the SwITCH OFF SwITCH ON mains by the phase fuse, the circuit-bre- aker or the switch-disconnector that are bistable joined to the proper circuit, relay 1 2. Check if there is no voltage on connec- tion cables by means of a special mea- sure equipment, 3. Install PBM-01 device in the switchboard on TH-35 DIN rail, 4. Connect the cables with the terminals bistable according to installing diagram, relay 2 5. Switch on the power supply from the mains, 6. Push the TEST button several times to check the relay operation correctness. The device is ready to work after switching on power supply. The relay operation correct- ness can be checked by pushing the TEST bistable button placed on the front panel. The system relay N should switch on and off the load connected to its output terminals. Mono modular pushbut- tons connected in a parallel way are available with backlit. Using the Set-Reset function the- Signal separator coordination SEM-01: re is a possibility of relay group central control. In the bistable control systems signal separators can be used After voltage fading the relay mode is remem- to divide control signals into particular relay groups. bered in the inner device memory. DIMENSIONS EXAMPLE OF INSTALLATION Typical use: The bistable relay ope- rating the staircase lighting (e.g. staircase lighting) are controlled by means of mono modular pushbuttons that can be connected in a paral- lel way. The buttons can be pla- ced in different places which gives the possibility of cre- ating universal lighting sy- stems control. PRODUCT FAMILY TIME COURSE RELAY CAPACITY The bistable relay PBM-02 belongs to bi- stable relay PBM product family. U t t IN INNER DIAGRAM SET t L N RESET t 14 IN IN 11 t IN T 11 S R GUARANTEE CARD There is 24 months guarantee on the product 1. ZAMEL provides a two-year warranty for its products. 2. The ZAMEL warranty does not cover: a) mechanical defects resulting from transport, loading / unloading or other circumstances, b) defects resulting from incorrect installation or operation of ZAMEL products, c) defects resulting from any changes made by CUSTOMERS or third parties, to products sold or equipment necessary for the correct operation of products sold, d) defects resulting from force majeure or other aleatory events for which ZAMEL is not liable. 3. All complaints in relation to the warranty must be provided by the CUSTOMER in writing to the retailer after discovering a defect. 4. ZAMEL will review complaints in accordance with existing regulations. 5. The way a complaint is settled, e.g. replacement of the product, repair or refund, is left to the discretion of ZAMEL. Salesman stamp and signature, date of sale ver. 0.4.2 2006.06.26 08:00