POWER LCM600 Data Sheet 600 Watt Bulk Front End Total Power: 600 W of Outputs: Single Outputs: 12 to 60 V Optional 5.0 V standby SPECIAL FEATURES 600 W output power Low Cost 2.4 x 4.5 x 7.5 7.41 W/cu-in Industrial/Medical safety Electrical Specifications -40 C to 70 C with derating Input Optional 5 V 2 A Housekeeping Input ra nge: 85 - 264 Vac (Operating) High Efficiency: 89% typical 115/230 Vac (Nominal) Input through standard IEC connector/ TERMINAL BLOCK Variable speed Smart Fans Frequency: 47 - 440 Hz, Nominal 50/60 DSP controlled front end Conformal coat option Input fusing: Internal 10 A fuses, both lines fused 20% adjustment range Inrush current: 25 A peak, either hot or cold start Margin programming Power factor: 0.99 typical, meets EN61000-3-2 OR-ing FET Harmonics: Meets IEC 1000-3-2 requirements Terminal block input option Input current: 8 A RMS max input current, at 100 Vac Hold up time: 20 ms minimum for Main O/P, at full rated load COMPLIANCE Efficiency: > 89% at full load EMI Class B Leakage current: < 0.3 mA at 264 Vac EN61000 Immunity ON/OFF power switch: N/A Power line transient: MOV directly after the fuse SAFETY Isolation: UL 60950-1 Isolation: PRI-Chassis 2500 Vdc Basic PRI-SEC 4000 VAC Reinforced 2xMOPP 1598/1433 SEC-Chassis 500 Vdc 60601-1 CSA 60950-1 VDE 60950-1 LCM600Q Ef ciency Without the 5 Vsb 60601 92.00 China CCC 90.00 CB Scheme Report/Cert 88.00 86.00 100 Vac 84.00 230 Vac 82.00 80.00 78.00 76.00 25 50 75 100 Loading % Ef ciency %LCM600 Data Sheet Electrical Specifications Output Output rating: See ordering information table 85 - 264 Vac Set point: 0.5% 85 - 264 Vac Total regulation range: Main output 2% Combined line/load/transient when measured at output 5 Vsb 1% terminal Rated load: 600 W maximum Derate linear to 50% from 50 C to 70 C Minimum load: Main output 0.0 A No loss of regulation 5 Vsb 0.0 A Output noise (PARD): 1% max p-p Main output 50 mV max p-p 5 Vsb output Measured with a 0.1 F Ceramic and 10 F Tantalum Capacitor on any output, 20 MHz Output voltage overshoot: No overshoot/undershoot outside the regulation band during on or off cycle Transient response: < 300 Sec 50% load step 1 A/s Step load valid between 10% to 100% of output rating Recovery time to within 1% of set point at onset of transient Max units in parallel: Up to 10 Short circuit protection: Protected, no damage to occur Bounce mode Remote sense: Compensation up to 500 mV Output isolation: Standard per safety requirements Forced load sharing: To within 10% of all shared outputs Analog sharing control Overload protection (OCP): 105% to 125% Main output 120% to 170% 5 Vsb output Overvoltage protection (OVP): 125% to 145% 12 V output 110% to 125% 5 Vsb output Overtemp protection: 10 - 15 C above safe operating area Both PFC and output converter monitored Fan Fault Protection: For-N option only. Will shutdown output and DC OK Environmental Specifications Operating temperature: -40 C to +70 C, linear derating to 50% from 50 C to 70 C Storage temperature: -40 C to +85 C Humidity: 20 to 90%, non-condensing. Operating. Conformal coat option available Fan noise: < 45 dBA, 80% load at 30 C -N Low Noise Option < 35 dBA, 80% Load at 30 C Altitude: Operating - 16,404.2 feet Storage - 30,000 feet Shock: MIL-STD-810F 516.5, Procedure I, VI. Storage Vibration: MIL-STD-810F 514.5, Cat. 4, 10. Storage Ordering Information Current Model Nominal Output Set Point Output Ripple Max Continuous Combined Line/ Number* Output Voltage Set Point Tolerance Adjustment Range Min Max P/P (0-50 C) Power Load Regulation LCM600L 12 V 12 V 0.5% 9.6 - 14.4 V 0 A 52 A 120 mV 600 W 2% LCM600N 15 V 15 V 0.5% 12.0 - 19.5 V 0 A 44 A 150 mV 600 W 2% LCM600Q 24 V 24 V 0.5% 19.2 - 28.8 V 0 A 27 A 240 mV 600 W 2% LCM600U 36 V 36 V 0.5% 28.8 - 43.2 V 0 A 16.7 A 240 mV 600 W 2% LCM600W 48 V 48 V 0.5% 38.4 - 57.6 V 0 A 14 A 280 mV 600 W 2% *Note: Add -T for terminal block instead of IEC input Add -N for low noise model on 12 V or 24 V models Add -4 for 5 V Standby output Add -A will be automatically added to all orders to denote new Aesthetics style chassis unless otherwise specified Example: a 24 V with terminal block, low noise and standby with new Aesthetics would be LCM600Q-T-N-4-A