POWER LPS60-M Series Data Sheet 60 Watts Medical Total Power: 60 - 80 Watts Input Voltage: 85-264 VAC 120-300 VDC of Outputs: Single SPECIAL FEATURES Medical safety approvals Universal input 3 x 5 footprint Remote sense Built in EMI filter Low output ripple Adjustable output voltage Overload protection Electrical Specifications 110 KHz switching frequency LPX60 enclosure kit available Input Input range 85 - 264 VAC (wide range), 120 - 300VDC SAFETY Frequency 47 - 440 Hz TUV EN 60950-1 Inrush current <18A peak 115VAC, <36A peak 230 VAC, cold start 25C EN 60601-1 Input current 1.5A max. (RMS) 115 VAC UL UL 2601-1 Efficiency 70% typical at full load CSA 22.2 No. 601.1 EMI filter FCC Class A conducted CISPR22 Class A conducted E182560 EN55022 Class A conducted VDE0878 PT3 Class A conducted CB IEC 60950-1 IEC 60601-1 Safety ground leakage current < 75A 50/60 Hz 264 VAC input CE Mark (LVD) Output Maximum power 60 W for convection 80 W with 30 CFM forced air Adjustment range -5, +10% minimum Hold-up time 20 ms 60 W load, 115 VAC nominal line Overload protection Short circuit protection on all outputs Case overload protected 110 - 145% above peak rating Overvoltage protection 5V output 5.7 - 6.7 VDC. Other outputs 10% to 25% above nominal output Remote sense Compensates for 0.5 V lead drop min. Will operate without remote sense connected Reverse connection protectedLPS60-M Series Data Sheet Environmental Specifications Operating temperature 0 to 50 C ambient. Derate each output as 2.5% per degree from 50 to 70 C, -20 C startup Storage temperature -40 C to +85 C Electromagnetic susceptibility Designed to meet IEC61000-4-2, -4-3, -4-4, -4-5, -4-6, Level 3 Humidity Operating non-condensing 5% to 95% RH Vibration Three orthogonal axes, sweep at 1cot/min, 5 min.dwell at four major resonances 0.75G peak 5Hz to 500 Hz, operational Temperature coefficient 0.04% per C MTBF demonstrated > 550,000 hours at full load and 25 C ambient conditions Ordering Information Maxlmun Load Maximun Load Model Output Minlmun Ripple 1 2 with Convection with 30CFM Peak Load Requlation 3 Number Voltaqe Load P/P(PARD) Cooling Forced Air LPS63-M 12 V 0A 5 A 6.7 A 7.5 A 2% 120 mV LPS64-M 15 V 0A 4 A 5.3 A 6 A 2% 150 mV LPS65-M 24 V 0A 2.5 A 3.3 A 3.8 A 2% 240 mV 1. Peak current lasting < 30 seconds with a maximum 10% duty cycle. 2. At 25 C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. Peak-to-peak with 20 MHz bandwidth and 10 F (tantalum capacitor) in parallel with a 0. F capacitor at rated line voltage and load ranges. Power Derating Curve 80W 30 CFM Forced Air Cooling 60W Output Power (Watts) 40W 40W Natural Convection 30W Cooling 20W 0W 0C 10C 20C 30C 40C 50C 60C 70C TA Ambient Temperature C