SIL 2 Powered Isolating Driver Smart-Hart compatible DIN-Rail D1020 Models D1020S, D1020D Characteristics: Technical Data: General Description: Supply: The single and dual channel DIN Rail Isolating Driver, D1020S and D1020D, isolates 24 Vdc nom (20 to 30 Vdc) reverse polarity protected, and transfers a 4-20, 0-20 mA signal from a controller located in Safe Area to a load of ripple within voltage limits 5 Vpp. up to 750 in Hazardous Area. It has a high output capacity of 15 V at 20 mA Current consumption 24 V: 95 mA for 2 channels D1020D, combined with a low drop across its input terminals. 50 mA for 1 channel D1020S with 20 mA output typical. The circuit allows bi-directional communication signals, for Smart I/P. Power dissipation: 1.9 W for 2 channels D1020D, 1.0 W for 1 channel D1020S In the 4-20 mA input range, a field open circuit reflects a high impedance to the control with 24 V supply voltage and 20 mA output typical. device output circuit. Max. power consumption: at 30 V supply voltage and overload condition, Function: 2.7 W for 2 channels D1020D, 1.4 W for 1 channel D1020S. 1 or 2 channels I.S. mA analog output for 2 wire I/P Smart converters or valve Isolation (Test Voltage): positioners, provides 3 port isolation (input/output/supply). I.S. Out/In 1.5 KV I.S. Out/Supply 1.5 KV I.S. Out/I.S. Out 500 V Signalling LED: In/Supply 500 V In/In 500 V. Power supply indication (green). Input: Smart Communication Frequency Band: 0/4 to 20 mA with 2.0 V voltage drop, reverse polarity protected. 0.5 to 40 KHz within 3 dB (Hart and higher frequency protocols). Output: EMC: 0/4 to 20 mA, on max. 750 load, current limited at 23 mA. Fully compliant with CE marking applicable requirements. Response time: 50 ms (10 to 90 % step change). Output ripple: 20 mVrms on 250 communication load on 0.5 to 40 KHz band. Functional Safety Management Certification: Frequency response: 0.5 to 40 KHz bidirectional within 3 dB FSM G.M. International is certified by TUV to conform to IEC61508:2010 (Hart and higher frequency protocols). SIL 3 part 1 clauses 5-6 for safety related systems up to and included SIL3. Performance: Ref. Conditions 24 V supply, 250 load, 23 1 C ambient temperature. Calibration accuracy: 0.1 % of full scale. Linearity error: 0.05 % of full scale. Supply voltage influence: 0.05 % of full scale for a min to max supply change. Load influence: 0.05 % of full scale for a 0 to 100 % load resistance change. Temperature influence: 0.01 % on zero and span for a 1 C change. Compatibility: CE mark compliant, conforms to Directive: 2014/34/EU ATEX, 2014/30/EU EMC, 2014/35/EU LVD, 2011/65/EU RoHS. Environmental conditions: Operating: temperature limits -20 to + 60 C, relative humidity max 95 %. Storage: temperature limits 45 to + 80 C. Safety Description: Front Panel and Features: ATEX: II (1)G Ex ia Ga IIC, II (1)D Ex ia Da IIIC, I (M1) Ex ia Ma I II 3G Ex nA IIC T4 Gc 1 2 3 4 SIL 2 according to IEC 61508:2010 Ed.2 for IECEx / INMETRO: Ex ia Ga IIC, Ex ia Da IIIC, Ex ia Ma I Ex nA IIC T4 Gc Tproof = 3 / 10 years (10% / >10 % of total SIF). UL: NI / I / 2 / ABCD / T4, AIS / I, II, III / 1 / ABCDEFG, AEx nC ia IIC PFDavg (1 year) 2.60 E-04, SFF 62.04 %. C-UL: NI / I / 2 / ABCD / T4, AIS / I, II, III / 1 / ABCDEFG, Ex nC ia IIC 5 6 7 8 SIL 3 Systematic capability. FM: NI / I / 2 / ABCD / T4, NI / I / 2 / IIC / T4, AIS / I, II, III / 1 / ABCDEFG, AEx ia IIC FM-C: NI / I / 2 / ABCD / T4, NI / I / 2 / IIC / T4, AIS / I, II, III / 1 / ABCDEFG, Ex ia IIC 2 fully independent channels. EAC-EX: 2Ex nA ia Ga IIC T4 Gc X, Ex ia Da IIIC X, Ex ia Ma I X Output to Zone 0 (Zone 20), Division 1, UKR TR n. 898: 2ExnAiaIICT4 X, ExiaI X installation in Zone 2, Division 2. associated apparatus and non-sparking electrical equipment. 4-20 or 0-20 mA Input, Output Signal. Uo/Voc = 25.2 V, Io/Isc = 87 mA, Po/Po = 548 mW at terminals 14-15, 10-11. Um = 250 Vrms, -20 C Ta 60 C. Wide Band Smart Communication, Approvals: Hart compatible. DMT 01 ATEX E 042 X conforms to EN60079-0, EN60079-11, EN60079-26. Field open circuit detection. IECEx BVS 07.0027X conforms to IEC60079-0, IEC60079-11, IEC60079-26. High Accuracy. IMQ 09 ATEX 013 X conforms to EN60079-0, EN60079-15. 1 2 IECEx IMQ 13.0011X conforms to IEC60079-0, IEC60079-15. Three port isolation, Input/Output/Supply. PWR ON INMETRO DNV 13.0108 X conforms to ABNT NBR IEC60079-0, ABNT NBR IEC60079- EMC Compatibility to EN61000-6-2, EN61000-6-4, EN61326-1. 11, ABNT NBR IEC60079-15, ABNT NBR IEC60079-26, ABNT NBR IEC 61241-11. UL & C-UL E222308 conforms to UL913, UL 60079-0, UL60079-11, UL60079-15, ATEX, IECEx, UL & C-UL, FM & FM-C, INMETRO, EAC-EX, ANSI/ISA 12.12.01 for UL and CSA-C22.2 No.157-92, CSA-E60079-0, CSA-E60079-11, UKR TR n. 898, TV Certifications. CSA-C22.2 No. 213 and CSA-E60079-15 for C-UL. TV Functional Safety Certification. FM & FM-C No. 3024643, 3029921C, conforms to Class 3600, 3610, 3611, 3810, D1020 Type Approval Certificate DNV and KR for ANSI/ISA 12.12.02, ANSI/ISA 60079-0, ANSI/ISA 60079-11, C22.2 No.142, maritime applications. C22.2 No.157, C22.2 No.213, E60079-0, E60079-11, E60079-15. C-IT.MH04.B.00306 conforms to GOST R IEC 60079-0,GOST R IEC 60079-11, High Reliability, SMD components. 9 10 11 12 GOST R IEC 60079-15. High Density, two channels per unit. C 16.0034 X conforms to 7113, 22782.5-78, I 60079-15. Simplified installation using standard TV Certificate No. C-IS-236198-03, SIL 2 conforms to IEC61508:2010 Ed.2. 13 14 15 16 DIN Rail and plug-in terminal blocks. TV Certificate No. C-IS-236198-09, SIL 3 Functional Safety Certificate conforms to IEC61508:2010 Ed.2, for Management of Functional Safety. 250 Vrms (Um) max. voltage allowed to the DNV No.A-13778 and KR No.MIL20769-EL001 Certificates for maritime applications. instruments associated with the barrier. Mounting: Ordering Information: T35 DIN Rail according to EN50022. Weight: about 180 g D1020D, 120 g D1020S. Model: D1020 Connection: by polarized plug-in disconnect screw terminal blocks to accomodate 2 terminations up to 2.5 mm . 1 channel S Location: Safe Area/Non Hazardous Locations or Zone 2, Group IIC T4, Class I, Division 2, Groups A, B, C, D Temperature Code T4 and 2 channels D Class I, Zone 2, Group IIC, IIB, IIA T4 installation. Power Bus enclosure /B Protection class: IP 20. Power Bus and DIN-Rail accessories: Dimensions: Width 22.5 mm, Depth 99 mm, Height 114.5 mm. DIN rail anchor MCHP065 DIN rail stopper MOR016 Terminal block male MOR017 Terminal block female MOR022 G.M. International DTS0017-17 Page 1/2 www.gmintsrl.com Parameters Table: Image: Safety Description Maximum External Parameters Group Co/Ca Lo/La Lo/Ro Cenelec (F) (mH) (H/) Terminals 14-15, 10-11 Uo/Voc = 25.2 V IIC 0.105 4.6 64.9 Io/Isc = 87 mA IIB 0.819 18.7 259.6 Po/Po = 548 mW IIA 2.899 37.5 519.3 I 4.15 61.5 851.9 IIIC 0.819 18.7 259.6 NOTE for USA and Canada: IIC equal to Gas Groups A, B, C, D, E, F and G IIB equal to Gas Groups C, D, E, F and G IIA equal to Gas Groups D, E, F and G Function Diagram: HAZARDOUS AREA ZONE 0 (ZONE 20) GROUP IIC, SAFE AREA, ZONE 2 GROUP IIC T4, HAZARDOUS LOCATIONS CLASS I, DIVISION 1, GROUPS A, B, C, D, NON HAZARDOUS LOCATIONS, CLASS I, DIVISION 2, CLASS II, DIVISION 1, GROUPS E, F, G, CLASS III, DIVISION 1, GROUPS A, B, C, D T-Code T4, CLASS I, ZONE 2, GROUP IIC T4 CLASS I, ZONE 0, GROUP IIC MODEL D1020D 3 + = = Ch1 Supply 24 Vdc 4 - = HHT HHT I/P Converter Source I 14 1 + + P = Out 1 In 1 15 2 I = - - 7 + = = Ch2 Supply 24 Vdc 8 - = HHT HHT I/P Converter Source I + 10 5 + P = Out 2 In 2 11 6 I = - - MODEL D1020S 3 + = = Supply 24 Vdc 4 - = HHT HHT I/P Converter Source I 14 1 + + P = Out 1 In 1 15 2 I = - - G.M. International DTS0017-17 Page 2/2