Series PVR13NPbF Microelectronic Power IC HEXFET Power MOSFET Photovoltaic Relay Dual-Pole, Normally-Open, 0-100V AC/DC, 360mA General Description Features The PVR13 Series AC/DC Relay is a dual-pole, normally open, solid-state replacement for Bounce-Free Operation electromechanical relays used for general purpose 10 10 Off-State Resistance switching of analog signals. It utilizes International 1,000 V/sec dv/dt Rectifiers HEXFET power MOSFETs as the output 0.2 V Thermal Offset switches, driven by an integrated circuit photovoltaic 5 mA Input Sensitivity generator of novel construction. The output switch is 1,500 V I/O Isolation controlled by radiation from a GaAlAs light emitting RMS Solid-State Reliability diode (LED), which is optically isolated from the photovoltaic generator. The PVR13 Series overcomes the limitations of both conventional electromechanical and reed relays by offering the solid state advantages of long life, fast operating speed, low pick up power, bounce-free operation, low thermal offset voltages and miniature package. These advantages allow product improvement and design innovations in many applications such as process control, multiplexing, automatic test equipment and data acquisition. The PVR13 can switch analog signals from thermocouple level to 100 Volts peak AC or DC polarity. Signal frequencies into the RF range are easily controlled and switching rates up to 450Hz are achievable. The extremely small thermally generated offset voltages allow increased measurement accuracies. These relays are packaged in 16-pin, molded DIP packages and available with thru-hole leads, in plastic shipping tubes. Applications Part Identification Process Control PVR1300NPbF Data Acquisition PVR1301NPbF Test Equipment Multiplexing and Scanning (HEXFET is the registered trademark for International Rectifier Power MOSFETs) 1 www.irf.com 2015 International Rectifier Submit Datasheet Feedback June 02, 2015Series PVR13NPbF Electrical Specifications (-40C T +85C unless otherwise specified) A INPUT CHARACTERISTICS Units Minimum Control Current A Connection (see figure 1) DC For 400 Continuous Load Current 2.0 mA 25C For 360 Continuous Load Current 5.0 mA 40C For 250 Continuous Load Current 5.0 mA 85C Minimum Turn-Off Current 10 A(DC) Minimum Turn-Off Voltage 0.6 V(DC) Control Current Range (Caution: current limit input LED. See figure 6) 2.0 to 25 mA(DC) Maximum Reverse Voltage 6.0 V(DC) OUTPUT CHARACTERISTICS Units Operating Voltage Range 100 V (peak) Maxiumum Load Current 40C I = 5mA (see figure 1) LED AC (A Connection) 360 mA (peak) DC (B Connection) 420 mA(DC) DC (C Connection) 660 mA(DC) Response Time 25C (see figures 7 and 8) Maximum T 12mA Control, 100 mA Load, 100 VDC 150 s (on) Maximum T 12mA Control, 100 mA Load, 100 VDC 125 s (off) Maximum On-state Resistance 25C (Pulsed) (fig. 2) 50 mA Load, 5mA Control AC (A Connection) 5 DC (B Connection) 3.0 DC (C Connection) 1.5 8 Minimum Off-state Resistance 25C 80 VDC PVR1300 10 10 80 VDC PVR1301 10 Maximum Thermal Offset Voltage 5.0mA Control 0.2 volts Minimum Off-State dv/dt 1000 V/s Typical Output Capacitance (see figure 9) 12 pF 50VDC GENERAL CHARACTERISTICS Units Dielectric Strength: Input-Output 1500 V RMS 12 Insulation Resistance: Input-Output 500V 10 DC Maximum Capacitance: Input-Output 1.0 pF Maximum Lead Soldering Temperature (1.6mm below seating plane for 10 sec.) 260 C Ambient Temperature Range: Operating -40 to +85 C Storage -40 to +100 International Rectifier does not recommend the use of this product in aerospace, avionics, military or life support applications. Users of this International Rectifier product in such applications assume all risks of such use and indemnify International Rectifier against all damages resulting from such use. 2 www.irf.com 2015 International Rectifier Submit Datasheet Feedback June 02, 2015