2000~6000W Front End Power System RKP-1 U Rac k Sys t em Features : Universal AC input / Full range Holds up to 3 power modules Active current sharing up to 6000W(3 unit) in one 19 rack, 3 rack max. can be operated in parallel (up to 9 units) PMBus serial interface IEC320-C20 or terminal block input Front-end & rectifier applications Stackable for system expansion Low profile: 1U height, 19 rack mount Hot swappable modules Output voltage trimming function 3 years warranty Description : RCP-2000 rack power system is an advanced 19 rack-mounted power system containing up to 3 hot-swappable RCP-2000 rectifiers and can deliver up to 6000W in the single rack. Up to 3 racks can be stacked to provide expanded total system capability up to 18,000W that are especially suitable for the application of servers, information technology equipment, networking, telecommunications, and wide range of industrial applications using distributed power architecture Note.8. Equipped with PMBus communication protocol, RCP-2000 rack system can be controlled or monitored by external device such as monitoring unit (RCP-CMU-1) or PC. SELECTION GUIDE Rack: RKP-1U I - CMU1 Whole System: RKP-6K1U I - CMU1 - 12 Output voltage CMU1: With RKP-CMU1 CMU1: With RKP-CMU1 -: Without RKP-CMU1 -: Without RKP-CMU1 I: AC Inlet (IEC320-C20) I: AC Inlet (IEC320-C20) T: Terminal block T: Terminal block SPECIFICATION - Rack System MODEL RKP-6K1U -12 RKP-6K1U -24 RKP-6K1U -48 MODULE RCP-2000-12 RCP-2000-24 RCP-2000-48 RACK RKP-1UI or RKP-1UT OUTPUT VOLTAGE 12V 24V 48V OUTPUT MAX. OUTPUT CURRENT 300A 240A 126A MAX. OUTPUT POWER Note.6 3600W 5760W 6048W VOLTAGE RANGE Note.5 90 ~ 264VAC 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz INPUT 13A/115VAC 7A/230VAC 16A/115VAC 11A/230VAC 16A/115VAC 11A/230VAC AC CURRENT (Typ.)FOR EACH UNIT <3.5mA / 230VAC LEAKAGE CURRENT 5V 0.3A, 12V 0.8A AUXILIARY POWER By electrical signal or dry contact ON:short OFF:open REMOTE ON/OFF CONTROL Compensate voltage drop on the load wiring up to 0.5V.Local Sensshould be connected in order to get the correct output voltage if theRemote Sensis not used REMOTE SENSE DC OK SIGNAL The isolated TTL signal out, refer to function manual FUNCTION AC FAIL SIGNAL The isolated TTL signal out, refer to function manual Adjustment of output voltage, possible between 90 ~ 110% of rated output OUTPUT VOLTAGE TRIM Logic Hig for over temperature warning, refer to function manual, isolated signal OVER TEMP WARNING FAN FAIL SIGNAL The isolated TTL signal out, refer to function manual -40 ~ +70 (Refer toDerating Curv) WORKING TEMP. 20 ~ 90% RH non-condensing WORKING HUMIDITY STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH ENVIRONMENT TEMP. COEFFICIENT 0.03%/ (0 ~ 50 ) VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS UL60950-1, TUV EN60950-1 approved WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.7KVDC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH EMC (Note 4) Compliance to EN55022 (CISPR22) Conduction Class B, Radiation Class A EN61000-3-2,-3 EMC EMISSION EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A DIMENSION Rack 483.6*350.8*44(L*W*H) OTHERS 14.1Kg 1pcs/14.1Kg/2.67CUFT PACKING 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. NOTE 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12 twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Derating may be needed under low input voltages. Please check the static characteristics for more details. 6. Output of all the RCP-2000 modules are connected in parallel in the rack. 7. Under parallel operation of more than one rack connecting together, ripple of the output voltage may be higher than the SPEC at light load condition. It will go back to normal ripple level once the output load is more than 10%. 8. Because of component tolerance, there is a possibility that some of units connected in parallel will reach an overcurrent limit then overloading the other units when operating at full load condition. If overload conditions happen in parallel usage, it is suggested that derate the total output current by 10%. File Name:RKP-1U RACK SYSTEM-SPEC 2015-02-112000~6000W Front End Power System R KP -1 U R a ck S ys tem Mechanical Specification (Rack System) Case No. 959A Unit:mm Fig1 14 25 1 13 ADDRESS ADDRESS ADDRESS SWITCH SWITCH SWITCH - + CN500 JK1 C B A Fig2 RKP-1UT FG N L FG N L FG N L 10 8.2 10 8 8.2 10 8.2 8 1 1 8 ADDRESS ADDRESS ADDRESS SWITCH SWITCH SWITCH - + CN500 JK1 C B A RKP-1UI Mounting Bracket IEC320-C20 IEC320-C20 IEC320-C20 440 SVR1 SVR1 SVR1 22 22 46 Air flow direction Module C Module B Module A 10.2 DC OK DC OK DC OK 466.1 483.6 File Name:RKP-1U RACK SYSTEM-SPEC 2015-02-11