NE5532, SA5532, SE5532, NE5532A, SE5532A Internally Compensated Dual Low Noise Operational Amplifier NE5532, SA5532, SE5532, NE5532A, SE5532A + Figure 1. Equivalent Schematic (Each Amplifier) MAXIMUM RATINGS Rating Symbol Value Unit Supply Voltage V 22 V S Input Voltage V V V IN SUPPLY Differential Input Voltage (Note 1) V 0.5 V DIFF Operating Temperature Range T C amb NE5532/A 0 to 70 SA5532 40 to +85 SE5532/A 55 to +125 Storage Temperature T 65 to +150 C stg Junction Temperature T 150 C j Maximum Power Dissipation, T = 25C (Still-Air) P mW amb D 8 D8 Package 780 8 N Package 1200 16 D Packagee 1200 Thermal Resistance, JunctiontoAmbient R C/W JA 8 D8 Package 182 8 N Package 130 16 D Packagee 140 Lead Soldering Temperature (10 sec max) T 230 C sld Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect device reliability. 1. Diodes protect the inputs against overvoltage. Therefore, unless current-limiting resistors are used, large currents will flow if the differential input voltage exceeds 0.6 V. Maximum current should be limited to 10 mA.