Ordering number : EN7437D TND027SW Excellent Power Device Ta=85C 25C --40C TND027SW Electrical Characteristics at Ta=25C Ratings Parameter Symbol Conditions Unit min. typ. max. Drain-to-Source Clamp Voltage V clamp V =0V, I =1mA 60 V DS, IN O I 1V =0V, V =50V 10 A DSS IN DS Output-OFF Current I 2V =0V, V =12V 5 A DSS IN DS Input Threshold Voltage V V =5V, I =1mA 1.0 1.5 2.0 V (th) IN DS O Protection Circuit Operating Input Voltage V(opr) 410V IN Drain-to-Source ON Resistance R (on) V =5V, I =1A 0.3 0.4 DS IN O Input Current (Output On) I V =5V 0.6 mA IN IN Over-Heat Detecting Temperature Tj(sd) V =5V, I =1A 120 150 190 C IN O Over-Current Detecting Current Is V =5V 3.0 6.0 9.0 A IN Over-Current Limit (Peak) I V =5V 3.0 6.0 9.0 A LMT IN Input Clamp Voltage V clamp I =1mA 10 V IN, IN Notes : 1. Overcurrent protection circuit limits the output current to the range of overcurrent limit value. 2. During overheat protecting operation, output current is turned off. Ordering Information Devices Package Shipping memo TND027SW-TL-2H SOIC8 2,500pcs./reel Pb Free and Halogen Free R (on) -- Ta R (on) -- V DS DS IN 0.5 1.0 I =1A I =1A O O 0.4 0.8 0.3 0.6 0.2 0.4 0.1 0.2 0 0 --50 --25 0 25 50 75 100 02468 10 12 Ambient Temperature, Ta -- C IT05233 Input Voltage, V -- V IT05234 IN I -- Ta I -- V IN IN IN 0.12 1.4 V =5V Ta=25C IN 1.2 0.10 1.0 0.08 0.8 0.06 0.6 0.04 0.4 0.02 0.2 0 0 --50 --25 0 25 50 75 100 02468 10 Ambient Temperature, Ta -- C IT05235 Input Voltage, V -- V IT05236 IN No.7437-2/9 I (normal) IN 6V 5V 4V I (abnormal) IN Drain-to-Source Input Current, I -- mA ON Resistance, R (on) -- IN DS Drain-to-Source Input Current, I -- mA ON Resistance, R (on) -- IN DS