QPC6054 5MHz to 6GHz Absorptive High Isolation SP5T Switch Product Overview The QPC6054 is a Silicon on Insulator (SOI) Single-Pole 5- Throw (SP5T) switch designed for uses in cellular, 3G, LTE and other high-performance communication systems. It offers a high isolation, identical throw ports with excellent linearity and power handling capability. No DC blocking capacitors are necessary on the RF ports. The design is 24-Pin, 4x4mm QFN Package non-reflective as such the RF1, RF2, RF3, RF4 and RF5 ports are terminated with 50 load(s) in the non-throw or All OFF state. The QPC6054 is 1.8V positive control logic Key Features compatible. It incorporates the control to disable the internal 56000MHz Operation Negative Voltage Generator (NVG) and the required negative voltage supplied by an off-chip external source to Single Pole 5 Throw the same pin. Non-Reflective RF1, RF2, RF3, RF4 & RF5 Ports, Terminated in ALL-OFF State No Blocking Capacitors Necessary Unless DC Voltage on RF line High Isolation: 60 dB at 2 GHz High Input IP3: +59 dBm +1.8 V Control Logic Compatible Applications Functional Block Diagram Cellular, 3G, 4G, 5G Infrastructure WiBro, WiMax, LTE High Performance Communication Systems Test Equipment Ordering Information Top View Part No. Description QPC6054TR13 2,500 pieces on a 13 reel (standard) 5 MHz 6GHz Evaluation Board QPC6054PCK410 with 5-piece samples Datasheet, Rev. K, January 10, 2020 Subject to change without notice 1 of 12 www.qorvo.com QPC6054 5 MHz to 6 GHz Absorptive High Isolation SP5T Switch Absolute Maximum Ratings Recommended Operating Conditions Parameter Rating Parameter Min Typ Max Units Storage Temperature 55 to +150C Device Voltage (VDD) +2.7 +5.0 +5.5 V Device Voltage (VSS), External RF Input Power, non-internally terminated +37.5 dBm -5.5 -5.0 -2.7 V Negative Voltage Supply RF Input Power, RFX terminated +29 dBm Device Voltage (VSS), Internal 0 V (VDD) +6 V Negative Voltage Generator Device Voltage (VSS) -6 V T 40 +25 +105 C CASE 6 Control Voltage (V1, V2, V3) Low / High -0.2 V / +6 V Tj for 10 hours MTTF +125 C Exceeding any one or a combination of the Absolute Maximum Rating Electrical specifications are measured at specified test conditions. conditions may cause permanent damage to the device. Extended Specifications are not guaranteed over all recommended operating application of Absolute Maximum Rating conditions to the device may conditions. reduce device reliability. Electrical Specifications (1) Parameter Conditions Min Typ Max Units Operational Frequency Range 5 6000 MHz 450 MHz 0.95 1.15 dB 900 MHz 1.00 1.20 dB (2) 2100 MHz 1.10 1.30 dB Insertion Loss (RFC to RF1/RF2/RF3/RF4/RF5) 2600 MHz 1.17 1.40 dB 4000 MHz 1.40 1.70 dB 6000 MHz 1.90 2.20 dB Group Delay ON Path 0.1 0.5 ns 450 MHz 61 70 dB 900 MHz 57 63 dB 2100 MHz 48 56 dB (3) Isolation 2600 MHz 48 54 dB (RFC to RF1/RF2/RF3/RF4) 4000 MHz 45 50 dB 5000 MHz 45 50 dB 6000 MHz 40 50 dB 450 MHz 61 70 dB 900 MHz 56 66 dB 2100 MHz 50 59 dB (3) Isolation 2600 MHz 48 56 dB (RF1/2/3/4/5 to RF1/2/3/4/5) 4000 MHz 43 50 dB 5000 MHz 41 48 dB 6000 MHz 38 44 dB (3) Isolation (RF1 RF4) 3500 MHz 50 56 dB (4) Isolation (RF2RF1, RF2 ON) 5000 MHz 41 42.3 dB (4) Isolation (RF3RF2, RF3 ON) 5000 MHz 41 42.8 dB (4) Isolation (RF4RF3, RF4 ON) 5000 MHz 43 44.8 dB (4) Isolation (RF5RF4, RF5 ON) 5000 MHz 40 41.7 dB (4) Isolation (RF5RF1, RF5 ON) 5000 MHz 43 45 dB Notes: 1. Test conditions unless otherwise noted: VDD= +5V V1, V2 and V3 = 0/+5V T =+25C Standard application circuit 50 system, A 2. PCB trace loss deducted 3. Isolation based on an optimized evaluation board 4. Only these RF path-ports listed, and the other ports isolation is better. Datasheet, Rev. K, January 10, 2020 Subject to change without notice 2 of 12 www.qorvo.com