QPC6064 5MHz to 6GHz Absorptive High Isolation SP6T Switch Product Overview The QPC6064 is a Silicon on Insulator (SOI) Single-Pole 6- Throw (SP6T) switch designed for uses in cellular, 3G, LTE and other high-performance communication systems. It offers a high isolation, identical throw ports with excellent linearity and power handling capability. No DC blocking capacitors are necessary on the RF ports. The design is 24-Pin, 4x4mm QFN Package non-reflective as such the RF1, RF2, RF3, RF4, RF5 and RF6 ports are internally terminated with 50 load(s) in the non-throw or OFF state. The QPC6064 is +1.8V control Key Features logic compatible. It incorporates the control to disable the 56000MHz Operation internal Negative Voltage Generator (NVG) and the optional external negative voltage supplied to the same pin. Non-Reflective RF1, RF2, RF3, RF4, RF5 & RF6 Ports, Internally Terminated in OFF and All-OFF State No Blocking Capacitors Necessary Unless DC Voltage on RF line High Isolation: 50 dB at 2 GHz High Input IP3: +59 dBm +1.8 V Control Logic Compatible Applications Functional Block Diagram Cellular, 3G, 4G, 5G Infrastructure WiBro, WiMAX, LTE High Performance Communication Systems Test Equipment Ordering Information Part No. Description Top View QPC6064TR13 2,500 pieces on a 13 reel (standard) 5 MHz 6 GHz Evaluation Board QPC6064PCK401 with 5-piece samples Datasheet, Rev. K, January 15, 2020 Subject to change without notice 1 of 12 www.qorvo.com QPC6064 5 MHz to 6 GHz Absorptive High Isolation SP5T Switch Absolute Maximum Ratings Recommended Operating Conditions Parameter Rating Parameter Min Typ Max Units Storage Temperature 40 to +150C Device Voltage (VDD) +2.7 +5.0 +5.5 V Device Voltage (VSS), External RF Input Power, non-internally terminated +37.5 dBm -5.5 -5.0 -2.7 V Negative Voltage Supply RF Input Power, RFX internally terminated +29 dBm Device Voltage (VSS), Internal 0 V (VDD) +6 V Negative Voltage Generator Device Voltage (VSS) -6 V T 40 +25 +105 C CASE 6 Control Voltage (V1, V2, V3) Low / High -0.2 V / +6 V Tj for 10 hours MTTF +125 C Exceeding any one or a combination of the Absolute Maximum Rating Electrical specifications are measured at specified test conditions. conditions may cause permanent damage to the device. Extended Specifications are not guaranteed over all recommended operating application of Absolute Maximum Rating conditions to the device may conditions. reduce device reliability. Electrical Specifications (1) Parameter Conditions Min Typ Max Units Operational Frequency Range 5 6000 MHz 450 MHz 1.02 dB 900 MHz 1.07 dB 2100 MHz 1.18 1.30 dB Insertion Loss 2600 MHz 1.25 dB 4000 MHz 1.41 dB 6000 MHz 2.02 dB 450 MHz 72 dB 900 MHz 66 dB 2100 MHz, RF1/RF2/RF3/RF4/RF5 45 57 dB Isolation 2100 MHz, RF6 35 40 dB (RFC RF1/RF2/RF3/RF4/RF5/RF6) 2600 MHz 56 dB 4000 MHz 52 dB 6000 MHz 48 dB 450 MHz 65 dB 900 MHz 59 dB 2100 MHz 51 dB Isolation (RF1/2/3/4/5/6 RF1/2/3/4/5/6) 2600 MHz 49 dB 4000 MHz 44 dB 6000 MHz 40 dB Notes: 1. Test conditions unless otherwise noted: VDD= +5V V1, V2 and V3 = 0/+5V TA=+25C Standard application circuit 50 system, Datasheet, Rev. K, January 15, 2020 Subject to change without notice 2 of 12 www.qorvo.com