GPC130 Commercial/GPM130 Medical
130 Watt Global Performance Switchers
FEATURES:
Wide-range ac input 85-264 Vac
2-year warranty
Commercial Approved to UL1950, IEC950,
EN60950 and CSA22.2-234 L3
Medical Approved to UL2601-1, IEC601-1 and
CSA22.2 No. 601
Conducted EMI exceeds FCC Class B and CISPR 22
Class B (Commercial models) and CISPR 11 Class B
(Medical models)
marked to LVD
Power Fail
SPECIFICATIONS:
TTL- or CMOS-compatible output goes low (< 0.5V) 5 ms
Ac Input
before output voltage drops more than 4% below nominal
85-264 Vac, 47-63 Hz single phase. voltage upon loss of ac power. The signal is factory set to
trip on 84 to 94Vac brown-out depending upon incoming line
Input Current impedance and distortion. Other settings are available to the
Maximum input current at 120 Vac, 60 Hz with full rated output user through adjustment of built-in potentiometer.
load: 3.5 A
Output Noise
Hold-Up Time 0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode.
20 ms minimum from loss of ac input at full load, nominal line Measured with noise probe directly across output terminals of
(115 Vac). the power supply.
Output Power Transient Response
100 W continuous, 165 W peak; 130 W with 26 cfm air flow. Peak Main output500Sec typical response time for return to within
ratings are for 60 s maximum duration, 10% duty cycle. During 0.5% of final value for a 50% load step change. i/ t<0.2 A/s.
peak load condition, output regulation may exceed total Maximum voltage deviation is 3.5%. Startup/shutdown overshoot
regulation limits. less than 3%.
Overload Protection Remote Sense
Fully protected against short circuit and output overload. Short Provided as a standard feature on output 1.
circuit protection is cycling type power limit on outputs 1 & 2;
foldback type on outputs 3 & 4. Recovery after fault is automatic. Voltage Adjustment
See output ratings chart for additional notes or conditions. Built-in potentiometer adjusts voltage 5% on outputs 1 & 2.
Overvoltage Protection Overload Protection
Main outputs: 124% 12% typical. Factory set to begin power limiting at approximately 170 W.
Efficiency
EMI/EMC Compliance
70% at full rated load, nominal input voltage, depending on model All models include built-in EMI filtering to meet the following
and load distribution. emissions requirements:
EMI SPECIFICATIONS COMPLIANCE LEVEL
Turn-on Time Conducted Emissions GPC130 EN55022 Class B; FCC Class B
Less than 1 second at 120 Vac, 25C (inversely proportional to Conducted Emissions GPM130 EN55022 Class B; FCC Class B
input voltage and thermistor temperature). Static Discharge EN61000-4-2, 6 kV contact, 8 kV air
RF Field Susceptibility EN61000-4-3, 3 V/meter
Input Protection Fast Transients/Bursts EN61000-4-4, 2 kV, 5 kHz
Internal ac fuse provided. Designed to blow only if a catastrophic Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com.
failure occurs in the unit.
Commercial Leakage Current
Inrush Current 0.7 mA 254 Vac @ 60 Hz input.
Inrush is limited by internal thermistors. Inrush at 240 Vac under
cold start conditions will not exceed 34 A. Commercial Safety
Approved to UL1950, CSA22.2 No. 234 Level 3, IEC950 and
Temperature Coefficient EN60950. UL file #E135803 commercial; CSA #LR46516 all
models. The output(s) are intended for safety earthed Signal
0.03%/C typical on all outputs.
Output and Intermediate Circuits only. All dc outputs are SELV
under normal and single fault conditions.
Thermal Shutdown
Provided as a standard feature. Designed to protect unit from
Medical Leakage Current
prolonged overtemperature.
35 A 254 Vac @ 60 Hz input.
Environmental
Medical Safety
Designed for 0 to 50C operation at full rated output power;
Approved to UL2601, CSA22.2 No. 601 Level 3 and IEC601. UL
derate output current and total output power by 2.5% per C
file E116994; CSA #LR46516. The output(s) are intended for
above 50C. See Environmental and Packaging Specifications
safety earthed Signal Output and Intermediate Circuits only. The
on next page.
output(s) are not acceptable for patient connection without
additional isolation. All dc outputs are SELV under normal and
single fault conditions.
Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033
800-235-5929 805-486-4565 FAX 805-487-8911 www.condorpower.com
54GPC130 Commercial/GPM130 Medical 130 Watt Multiple Output
Commercial Medical Output Output Output Total
Model Model Output No. Output Minimum Maximum (B) Maximum (C) Output Peak Noise P-P Regulation (A)
GPC130A GPM130A 1 +5 V 3 A 16 A 20 A 25 A 50 mV 2%
2 +12 V 0 A 5 A 5 A 8 A 120 mV 2%
3 -12 V 0 A 1.2 A 1.2 A 1.5 A 120 mV 3%
4 +12 V 0 A 1.2 A 1.2 A 1.5 A 120 mV 3%
GPC130B GPM130B 1 + 5 V 3 A 16 A 20 A 25 A 50 mV 2%
2 +12 V 0 A 5 A 5 A 8 A 120 mV 2%
3 -5 V 0 A 1.2 A 1.2 A 1.5 A 50 mV 3%
4 -12 V 0 A 1.2 A 1.2 A 1.5 A 120 mV 3%
GPC130C GPM130C 1 +5 V 3 A 16 A 20 A 25 A 50 mV 2%
2 +12 V 0 A 5 A 5 A 8 A 120 mV 2%
3 -15 V 0 A 1.2 A 1.2 A 1.5 A 150 mV 3%
4 +15 V 0 A 1.2 A 1.2 A 1.5 A 150 mV 3%
GPC130D GPM130D 1 +5 V 3 A 16 A 20 A 25 A 50 mV 2%
2 +24 V 0 A 3.5 A 3.5 A 5 A 240 mV 2%
3 -12 V 0 A 1.2 A 1.2 A 1.5 A 120 mV 3%
4 +12 V 0 A 1.2 A 1.2 A 1.5 A 120 mV 3%
GPC130E GPM130E 1 +5 V 3 A 16 A 20 A 25 A 50 mV 2%
2 +24 V 0 A 3.5 A 3.5 A 5 A 240 mV 2%
3 -15 V 0 A 1.2 A 1.2 A 1.5 A 150 mV 3%
4 +15 V 0 A 1.2 A 1.2 A 1.5 A 150 mV 3%
A. Total regulation is defined as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load.
B. Unrestricted natural convection cooling.
C. Requires 26 cfm moving air.
GPC130/GPM130 MECHANICAL SPECIFICATIONS
Environmental
Operating Non-operating
Specification
o
Tsemperature (A)S5ee individual spec -40 to +8 C
HHumidity (A)0Hto 95% R 0 to 95% R
A. Units should be allowed to warm up/operate under non-condensing conditions
Sghock (B) 20 40 g
pk pk before application of power.
B. Random vibration10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3
Atltitude-t500 to 10,000 f -500 to 40,000 f
orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating.
C. Shock testinghalf-sinusoidal, 10 3 ms duration, direction, 3 orthogonal axes,
2 2
Vgibration (C) 1.5 , 0.003 g/gHz 5 , 0.026 g /Hz
rms rms total 6 shocks.
Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033
800-235-5929 805-486-4565 FAX 805-487-8911 www.condorpower.com
55