TSD3G Taiwan Semiconductor 3A, 400V ESD Capability Rectifier FEATURES KEY PARAMETERS High ESD capability PARAMETER VALUE UNIT Glass passivated chip junction I 3 A F Ideal for automated placement V 400 V RRM Low forward voltage drop High surge current capability I 100 A FSM Moisture sensitivity level: level 1, per J-STD-020 V at I =3A 1 V F F AEC-Q101 qualified available: T 175 C J MAX ordering code with suffix H Compliant to RoHS Directive 2011/65/EU and Package DO-214AB (SMC) in accordance to WEEE 2002/96/EC Configuration Single die Halogen-free according to IEC 61249-2-21 APPLICATIONS Switching mode power supply (SMPS) Adapters Lighting application Converter MECHANICAL DATA Case: DO-214AB (SMC) Molding compound meets UL 94V-0 flammability rating Terminal: Matte tin plated leads, solderable per J-STD-002 Meet JESD 201 class 2 whisker test Polarity: As marked Weight: 0.210 g (approximately) DO-214AB (SMC) SOLUTE MAXIMUM RATINGS (T = 25C unless otherwise noted) A SYMBOL TSD3G UNIT PARAMETER TSD3G Marking code on the device Repetitive peak reverse voltage V 400 V RRM Reverse voltage, total rms value V 280 V R(RMS) Forward current I 3 A F Surge peak forward current, 8.3ms single half sine-wave I 100 A FSM superimposed on rated load per diode T - 55 to +175 C Junction temperature J T - 55 to +175 C Storage temperature STG 1 Version: E2005 TSD3G Taiwan Semiconductor THERMAL PERFORMANCE PARAMETER SYMBOL TYP UNIT Junction-to-lead thermal resistance R 21 C/W JL Junction-to-ambient thermal resistance R 59 C/W JA Junction-to-case thermal resistance R 22 C/W JC Thermal Performance Note: Units mounted on PCB (16mm x 16mm Cu pad test board) ELECTRICAL SPECIFICATIONS (T = 25C unless otherwise noted) A PARAMETER CONDITIONS SYMBOL TYP MAX UNIT I = 1.5A, T = 25C 0.85 0.95 F J V I = 3.0A, T = 25C 0.89 1.00 V F J (1) Forward voltage V F I = 1.5A, T = 125C 0.72 0.90 V F J I = 3.0A, T = 125C 0.76 1.00 V F J T = 25C - 1 A J (2) Reverse current rated V I R R - 50 T = 125C A J 1MHz, V = 4.0V 45 - Junction capacitance R C pF J Notes: 1. Pulse test with PW = 0.3ms 2. Pulse test with PW = 30ms IMMUNITY TO ELECTRICAL STATIC DISCHARGE TO THE FOLLOWING STANDARDS (T = 25C unless otherwise noted) A Standard Test Type Test Conditions SYMBOL CLASS Value Typical Human body H3B 8kV AEC-Q101-001 C=100pF,R=1.5k N/A model(contact mode) 4 8kV Contact mode C=150pF,R=330 25kV IEC 61000-4-2 Vc 4 15kV Air-discharge mode C=150pF,R=330 30kV L4 15kV Contact mode C=330pF,R=330 25kV ISO 10605 L4 25kV Air-discharge mode C=330pF,R=330 30kV 2 Version: E2005