Data sheet Weidmller Interface GmbH & Co. KG TERMOPTO Klingenbergstrae 16 TOP 120VAC/48VDC 0,1A D-32758 Detmold Germany Fon: +49 5231 1429-0 Fax: +49 5231 14292083 www.weidmueller.com TERMOPTO solid-state relay 5 to 48 VDC 0.1 A output version, with AC or DC input, available in different versions: With PUSH IN connection In 6.1 mm width With various input protection circuits (free-wheel diode, varistor) Pluggable cross-connections Enclosed design General ordering data Type TOP 120VAC/48VDC 0,1A Order No. 8950880000 Version TERMOPTO, solid-state relais, 1 NO contact (Transistor), Rated control voltage: 120 V AC 20 % , Rated switching voltage: 5...48 V DC, Continuous current: 100 mA, PUSH IN GTIN (EAN) 4032248742257 Qty. 10 pc(s). Creation date June 13, 2017 10:53:11 AM CEST Catalogue status 02.06.2017 / We reserve the right to make technical changes. 1Data sheet Weidmller Interface GmbH & Co. KG TERMOPTO Klingenbergstrae 16 TOP 120VAC/48VDC 0,1A D-32758 Detmold Germany Fon: +49 5231 1429-0 Fax: +49 5231 14292083 www.weidmueller.com Technical data Dimensions and weights Width 6.1 mm Width (inches) 0.24 inch Height 79.4 mm Height (inches) 3.126 inch Depth 55 mm Depth (inches) 2.165 inch Net weight 19.7 g Temperatures Humidity 595% rel. humidity, T = Operating temperature u 40C, no condensation -20 C...60 C Storage temperature -40 C...80 C Probability of failure MTTF 2,500 Years Control side Rated control voltage 120 V AC 20 % Nominal control current 2.9 mA AC Power rating 0.3 VA Cut-in / dropout voltage 102 V / 48 V AC Status indicator No Protective circuit Varistor Load side Rated switching voltage 5...48 V DC Continuous current 100 mA Rated switching current 100 mA Load category DC1 Switch-on delay < 12 ms Switch-off delay < 14 ms Voltage drop at max. load < 1 V Leakage current < 10 A Min. switching current 100 A Short-circuit-proof No Protective circuit, load side max. switching frequency (AC control Free-wheel diode voltage) 10 Hz Contact data Contact type 1 NO contact (Transistor) General data UL 94 flammability rating V-0 Insulation coordination Rated voltage 300 V Pollution severity 2 Surge voltage category Clearance and creepage distances for III control side - load side > 3 mm Dielectric strength for control side - load Impulse withstand voltage 1.2 kV / 1 min. side eff 4 kV (1.2/50 s) Protection degree IP20 Further details of approvals / standards Standards DIN EN 50178, IEC Certificate no. (cULus) 62314, UL508 E223474 Creation date June 13, 2017 10:53:11 AM CEST Catalogue status 02.06.2017 / We reserve the right to make technical changes. 2