EXTA FREE CONTROLLER EFC-02 MINI COOPERATION WITH SEVERAL CONTROLLERS EFC-02 MANUAL INSTRUCTION Application EFC-02 is prepared to work with a greater number of controllers working in the local network. Such situation is possible in the case of large objects. The application automatically searches the start controllers working in a local network. If the number is bigger than> 1 it shows a list of active controllers. Controllers are differentiated known by their names. User by pressing the Connect selects the controller to which he wants to be logged. After selecting appears login window and then you need to enter ypur user name and password. If you already saved your login in the application it auto- matically goes to the main window. ZAMEL Sp. z o.o. SWITCHING BETWEEN THE CONTROLLERS ul. Zielona 27, 43-200 Pszczyna, Poland For easy switching between several controllers working in the same local network server bookmark Switch Controller available below the icon Configu- Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04 ration. Switching between controllers is available to users in the admin and user. www.zamel.com, e-mail: marketing zamel.pl The procedure is analogous to this as described in the Collaboration with several controllers. THE DESCRIPTION TECHNICAL SPECIFICATIONS SOFTWARE UPDATE OF CONTROLLER Software updates in the EFC-02 is made from a PC. Controller EFC-02 Mini after connec- EFC-02 Mini In order to update the software you needs: tion with the Wi-Fi router gives you the 1. Download the current version of the software from the www.zamel.com or www.extafree.pl. Nominal supply voltage: 5V DC / 1.2 A - standard of Micro USB opportunity to control all of the receir- 2. Connect the controller EFC-02 into a PCs USB port. Nominal power consumption: 1.6 W 3. Controller will report to the system as external memory by ZAMEL UPGRADE DISC vers of EXTA FREE system from the The type of battery to sustain the clock operation: CR2032 4. In order to update the software, remove the file *. bin directory located on the ZAMEL UPGRADE DISC and then copy a new file. level of the mobile divice. Apart from 5. After finishing copy process you need disconnect the controller from the PC. Durability of battery: 5 years the function of virtual transmitters 6. The software is updated. Communication system components of EXTA FREE: Radio f = 868 MHz, unidirectional controller EFC-02 Mini has the possi- Total radio modules: 1 bility of realization SCENES, THE TIME ACTIVE TABS IN THE PROGRAM FOR EFC-02 Range: Up to 250m in open area FUNCTIONS and the preview state of TRANSMITTERS Possibility to increase the range: Yes - via retransmitter RTN-01 sensors. All functionality of controller is Collection of all virtual transmitters used to control receivers of EXTA FREE system what was installed in your house. The appearance of transmit- included in the plastic case with leaded Possibility to connecting an external antenna: No ters alludes to physical transmitters system. atop the LED panel with signalizations. 802.11 a / b / g / n - pursued through the HOUSE Communication with mobile devices: connection with the Wi-Fi router Allows you to split the whole house system level - living room - the device. Tab allows for simple and clear management of all the devices in the A communication system carried out house to associated with the receivers EXTA FREE. Connectors: 1 x RJ45 Ethernet port, 1 x Micro USB B 2.0 with a receiver through a radio frequen- SCENES cy of 868.32 MHz.The controller is con- Firmware upgradeable: Yes - via USB port Allows you to define the specific sequence of events that you want to performing simultaneously or set delays. Scenes can be launched from the nected to the Wi-Fi router using a LAN Remote sccess service: Only for users with xed external IP address application or physical transmitter EXTA FREE.. TIMED OPERATION cable by completed RJ45 plug.Setting LEDs: 6 x LED Allows you to define the specific sequence of events that you want to perform at a specific time, day of week, month, or sequentially. Timed oper- and operation via the free application Operating temperature: -10 to + 55 C ations bring on automatically level of controller. installed on your mobile device. EFC-02 DETECTORS Position: free is designed for control within the local Tab enables to preview status or values derived from the registered application of the radio detectors: temperature, illuminance, flooding, Protection degree: IP20 (EN 60529) motion, etc. network. Remote access is available Protection class: III CONFIGURATION only to users who have constant access Tab allows you to enter basic settings configuration associated with users, network parameters, the remote access, language settings, etc. Dimensions: 160 x 100 x 32 mm to an IP address and has appropriate Compliance with the standards: PN-ETSI EN 300 220-1, ETSI EN 300 220-2 redirections on the router. LIMITATIONS THE APPEARANCE Limitations of the tabs: TRANSMITTERS / HOUSE/SCENES / TIMED OPERATIONS / DETECTORS The maximum number of transmitters to define the tab without limitation TRANSMITTERS Unlimited Maximum number of devices to define tab HOME Unlimited Maximum time for waiting key code during the cloning operation press END Maximum events (codes) creating a single stage 10 Power connector Maximum number of scenes can be defined in the tab without limitation SCENE Unlimited RESET button - restore the factory settings Maximum number of scenes in progress 20 Ethernet socket Maximum events (codes) creating single TIMED OPERATIONS 10 Maximum number of functions can be defined in the tab TIMED OPERATION 40 globally for all users Setting delay time 0 to 99 sec Settings until you press 0 to 99 sec Maximum number of detectors to define the tab DETECTORS 50 Error indicator SD card Maximum waiting time for sensor code during operation of adding detectors press END Indicator connection USB The indicator of receipt Gear indicator (broadcast) WARRANTY CARD LAN switch indicator 1. ZAMEL Sp. z o.o. assures 24 months guarantee for the product. There is 24 months guarantee on the product 2. The manufacturers guarantee does not cover any of the following actions: Power indicator a) mechanical damage during transport, loading / unloading or under other circumstances, b) damage caused by incorrect product mounting or misuse, c) damage caused by unauthorised modi cations made by the PURCHASER or any third parties to the product or any other devices needed for the product functioning, d) damage caused by Act of God or any other incidents independent of the manufacturer - ZAMEL Sp z o.o. e) supply sources (batteries) included in the device during selling (if they are included). 3. The PURCHASER shall lay any claims in writing to the dealer or ZAMEL Sp. z o.o. 4. ZAMEL Sp. z o.o. is liable for processing any claim according to current Polish legislation. The symbol stands for selective 5. ZAMEL Sp. z o.o. shall process the claim at its own discretion: product repair, replacement ormoney return. collection of electrical and electronic devices. Placing used devices with other 6. The manufacturers guarantee is valid in the Republic of Poland. waste is not allowed 7. The PURCHASERs statutory rights in any applicable legislation whether against the retailer arising from the Salesman stamp and signature, date of sale purchase contract or otherwise are not affected by this warranty. plik: inst ext en efc-02 mody kacja: 22.05.2014INSTALLATION CREATING USERS Before installation controller you need carefully read the manual instruction. The application serves for creating users tab Users available under the icon Configuration. Tab are visible only for users from admin group. In order to ensure of proper communication with many elements of system EXTA FREE controller EFC-02 Mini must be installed in the central part of the house. Radius of controller in the open air is up to 250 m, however in objects such as apartments / houses may be limited. This follows directly from the Maximum number of users possible for creations: 10 existing obstacles: walls, furniture, ceillings, etc. Maximum number of users logged to the EFC-02 controller: 5 EFC-02 controller do not put in metal enclosures / switchgears and in close vicinity devices which emiteing large electromagnetic distrurbance. EFC-02 controller must be necessarily connected to the Wi-Fi router. Router must be automatically assign IP addresses (DHCP unlocked). For connection Minimum usernames leight: 5 characters should be use free LAN port on the router. Maximum username length: 20 characters To launch and use the EFC-02 is not required for access to the Internet. Minimum password length: 5 characters Maximum password length: 20 characters power supply Special characters in usernames and passwords are not allowed. computer Wi-Fi router For creation a new user, log in to the application as admin, enter to the tabs USERS and click . Following the introduction of username and password, assign it to the appropriate group: user or admin. admin group the user has access to all application resources (con guration and control system). user group the users can only control. When that is necessary then editing options for user can be activated from the tab Enter to the edit mode. Switches on the option editing is possible only after signed in into user account from user groups. When using an application, you can assign a user to another group or change its password. This can be done only by user with admin group. For switching between users serves tab Log out. Used symbols: Signed in user assigned to the admin group Signed in user assigned to the user group Wiring scheme of controller EFC-02 Signed off user assigned to the admin group Signed off user assigned to the user group 1. EFC-02 controller connect into free LAN socket on the router using a standard UTP / FTP (cable islocated in sen with controller) 2. Plug in the plug USB Micro B adapter into the appropriate slot 5 V DC EFC-02 controller (the appropriate USB cable and power adapter Acceptance con guration by the user from user group are in set with controller). User from the group user during the rst sign for application can bene t from con guration created by the user from Admin group or con guration saved 3. Insert the AC adapter into a 230 VAC. previously to SD card. 4. Wait a minimum 30 sec for successful implementation of the controller and assign IP-address of Wi-Fi router. Speci ed readiness for operation LED lighting. New user after entering the correct username and password and press Sign In will be asked whether you want to take the settings of user from admin 5. If any problems with assignment IP-address of the router via port is set to Auto-negotiation (some of routers CISCO) switch the port to 10 Mbps speed. group or the SD card. Con rm your selection by clicking OK. If you do not select any option then the application will start with empty con guration. * ATTENTION Considering open air range concernes, ieideal condition without any obstacles.When between controller and transmitter / receive are obstac- If you select Accept administrator settings when you click OK will be displayed a list of users in the admin. Select the user whose settings you want les, then there must be reduction of radius depending of: brick 10 to 40%, wood and plaster from 5 to 20% of the ferroconcrete 40 to 80% of a metal from to take. Select con rm OK. 90 to 100% glass of 10 to 20%.Negative impacts on different activities are also ground and underground high electrical power lines and mobile phones arranged in the immediate proximity to the equipment. If you select Accept settings from SD card then you need click OK and will be displayed a list of users whose con guration is saved on the me- mory card. Select a user whose settings you want to take. Select con rm OK. In the case acquisition of con guration from SD card, save the con guration previously created on the SD card and install the card with device to which we hold con guration. APPLICATION EXTA FREE Copy con guration from the user admin group or SD-card is possible at any time of ling. Then select Copy Settings icon under Con guration.When using this option, you must also copy the con guration con rmed by the password of the sign in user. Configuration and control system EXTA FREE using EFC-02 Mini is achieved through the free app EXTA FREE. Acceptance con guration by the user from admin group The application can be downloaded directly from the www.zamel.com or www.extafree.pl The procedure similar as during taking over con guration by the user from user group. In this case, there is only ability to copy con guration from the from the Google Play shop ( for Android divices), memory card. from the App Store ( for iOS divices). The application is compatible with Android from the beginning of 2.3 version and iOS from the beginning of 6.0 version. Graphical appearance of apps maybe be different of model system depending. THE NETWORK SETTINGS FIRST START-UP OF APPLICATION Network settings entered in the Network Settings option under the icon Configuration. Tab are visible only for users from admin group. 1. The application must be successfully installed on your mobile device. Default in controller EFC-02 is active, DHCP Server service (the controller expects to assign him IP address through the router Wi-Fi). In connection with 2. Check correct connection of controller (inspector) EFC -02 with router Wi-Fi. necessary to release DHCP service on Wi-Fi router that is connected to the controller. 3. Check whether your mobile device is connected with Wi-Fi router cooperating with controller EFC-02. The controller has its own unique name under which is seen in the local network. 4.Check whether controller EFC-02 Mini is ready to work (illuminated controls) 5. Start up application EXTA FREE on mobile divice. Default controller name: EFC02-XXXX, where XXXX - attributed at the factory by the manufacturer serial number 6. After starting the application starts to search controllers EFC-02 connected to the router Wi-Fi. The name of the controller can be freely modified depending on your preference within the minimum and maximum number of characters: In the case of single controller after finding will appear: default name of the controller (DEFAULT No. - entered on the controller housing) Minimum length controller name 1 character IP adress of controller. Maximum length controller name 20 characters Data field for entering user name and password: default user name: admin, default password: admin. After pressing the Sign In will be redirected to the main window. When login process is completed successfully this is the signaled by In order to record the modified name of the controller, press the button . massage Logged in. The icons in the main window representing functions available for the EFC-02 are active. Can then be accede to configure In justified cases controller can be given fixed, individual network settings. To do this deselect service DHCP server and make the necessary settings: - IP and control system. address - Mask - Gateway When you log in, you can save data entered by checking options Remember Me. To save modified network settings, press the button . In this case after restarting application will be automatically redirected to the main window. To the logoff from the application serves buttonSign out in the application Configuration.If during the aplication time comes loss of communication with the controller then this message signals the Offline Mode. All icons in the app will be grayed out. Its necessary to closed this app and then kick-start again. REMOTE ACCESS If data entered during logging to the controller they are incorrect then this is indicated by a corresponding in the login window. Entry to the application is possible only after entering the correct data. ATTENTION: If controller EFC-02 remote access from outside local network is possible only for users which have an external fixed IP address. To launch remote access services first of all you need make an appropriate forwarding IP address / port on the router (in this purpose best contact is your network administrator) Then you need to log into the application as a user with admin group. In the tab Network Settings select the option Remote SET UP DATE AND TIME access and enter the external IP address and Port for which is set to redirect. The introduced settings apply globally to all resources of controller EFC-02 (all users associated with the controller). For correct usage of time functions necessary is corections data and time of application. To do that use the tab Date and Time available under the icon Default application operates on the port 2013. Configuration. Tab is visible only for users of the admin group. In order record modified network settings press the button . For saving settings you need press the button . After saving appears in messages: In case of remote access application immediately after starting begin to seach controllers EFC-02 in the local network. If it will be not found automatically Was changed date and time record setting completed successfully forced attempt to connect for remote IP and Port of specified. Error recording - record setting completed error For remote connection with controller EFC-02 need to be accessed to the Internet. When record completed with error then repeat please record test. plik: inst ext en efc-02 mody kacja: 22.05.2014