MANUAL INSTRUCTION RADIO LIGHTING SWITCH RWL-01 MOUNTING CAPACITY CAPACITY 1. Disconnect power supply by the phase fuse, the circuit-breaker or the switch- disconnector combined to the proper 100 W ZAMEL Sp. z o.o. circuit. 2. Check if there is no voltage on con- nection cables by means of a special measure equipment. The ZAMEL company ul. Zielona 27, 43-200 Pszczyna, Poland 100 W devices which are 3. Screw RWL-01 device into electric tel. +48 (32) 210 46 65, fax +48 (32) 210 80 04 characterised with this sign www.zamelcet.com, e-mail: marketing zamel.pl -light fitting. can cooperate 4. Screw light source into RWL-01 socket. with each other. 5. Switch on the power supply from DESCRIPTION TECHNICAL DATA the mains. RWL-01 Radio lighting switch RWL-01 ena- bles adaptation of any electric-light fitting Input rated voltage: 230 V AC APPLICATION with maximum 100W light source (E27 Input voltage tolerance: -15 +10 % thread) to wireless control in the range of Nominal frequency: 50 / 60 Hz EXTA FREE system. By placing RWL-01 Nominal power consumption: 0,29 W in electric-light fittings without the help of Number of operation modes: 5 any additional tools, it is possible to con- trol fittings by means of radio transmitters. Number of channels: 1 The switch can be used with low current Transmission: radio 868,32 MHz consumption devices, e.g. energy-saving Transmission way: unidirectional lighting as it uses only 0,29W. Coding: addressing transmission Maximum number of transmitters: 32 Range: up to 200 m in the open air Time adjustment: 1 second 18 hours (every 1 sec.) Optical signalling of transmitters operation: LED red diode FEATURES Maximum light source: 100 W o cooperation with wireless EXTA FREE Ambient temperature range: -10 +55 C control system transmitters, Operating position: free light source radio control directly in Casing mounting: electric-light fitting electric-light fitting, Casing protection degree: IP20 (PN-EN 60529) light source: maximum100W (light Protection level: II bulbs, compact fluorescent lamps), Overvoltage category: II 5 operation modes: switching on, Pollution degree: 2 switching off, monostable mode, bista- Surge voltage: 1 kV (PN-EN 61000-4-5) ble mode, Dimensions: 62,5 x 103 mm time mode (switch off delay), Weight: 0,099 kg wide operation range (up to 200 m), Reference standard: PN-EN 60669, PN-EN 60950, PN-EN 61000 operation is optically signalled, possibility of increasing operation range by means of RTN-01 retransmitter. APPEARANCE E27 lighting socket The device is designed for single-phase installation and must be installed in accord- ance with standards valid in a Radio lighting switch RWL-01 operates as a receiver of 8-channel remote controller P-256/8 and particular country. The device of 2-channel button radio transmitter RNK-02 (switch on/switch off control of a light source installed should be connected accord- CAUTION in E27 thread in RWL-01 device). The above mentioned transmitters can also control operation of ing to the details included in 1-channel flush receiver ROP-01 and of remote control socket RWG-01. this operating manual. Installation, connection and control should be carried out by a qualified Optical signalling of receivers operation electrician staff, who act in accordance with the service manual and the device functions. Dis- Programming buttons assembling of the device is equal with a loss of guarantee and can cause electric shock. Before installation make sure the connection cables are WARRANTY CARD not under voltage. The cruciform head screw- driver 3,5 mm should be used to instal the de- There is 24 months guarantee on the product vice. Improper transport, storage, and use of 1. ZAMEL provides a two-year warranty for its products. the device inufl ence its wrong functioning. It is 2. The ZAMEL warranty does not cover: a) mechanical defects resulting from transport, loading / unloading or other circumstances not advisable to instal the device in the following b) defects resulting from incorrect installation or operation of ZAMEL products c) defects resulting from any changes made by CUS- cases: if any device part is missing or the device TOMERS or third parties, to products sold or equipment necessary for the correct operation of products sold d) defects resulting E27 thread power supply from force majeure or other aleatory events for which ZAMEL is not liable e) power supply (batteries) to be equipped with a device is damaged or deformed. In case of improper in the moment of sale (if they appear) functioning of the device contact the producer. 3. All complaints in relation to the warranty must be provided by the CUSTOMER in writing to the retailer after discovering a defect. 4. ZAMEL will review complaints in accordance with existing regulations. The symbol means selective 5. The way a complaint is settled, e.g. replacement of the product, repair or refund, is left to the discretion of ZAMEL. collecting of electrical and electronic 6. Guarantee does not exclude, does not limit, nor does it suspend the rights of the PURCHASER resulting from the discrepancy equipment. It is forbidden to put between the goods and the contract. the used equipment together with other waste. Salesman stamp and signature, date of sale VER. 005 20.06.2011OPERATION TIME PROGRAMMING The device can operate in five modes: 1s 2s ns MONOSTABLE BISTABLE SWITCH ON TIME the relay operates only (one push-button) the the device switches on the device switches while pressing transmit- device changes relay after pressing the push- off according to the ters push-button. status cyclically always button. adjusted time (tp), after pressing the same push- SWITCH OFF but it may be switched off before button. the device switches off adjusted time finishes. Default Press PROG push-button of RWL-01 device for a longer time till Press PROG push-button of RWL-01 device After the adjusted time is after pressing the push- settings - 15 seconds. LED red diode switches on (constant signal). Next release PROG and then release it. LED red diode switches finished (the number of LED button. push-button. Wait (for about 5 seconds) till LED red diode switches off and then switches on (signal pulsates). red diode flashes) press CAUTION Adjusted time can on (first signal pulsates, next the signal is constant). Every LED diode pulse equals 1 second. PROG push-button and then not be deleted. release it - TIME IS ADDED. Maximum time is 18 hours for every channel. RADIO TRANSMITTERS DELETION RADIO TRANSMITTERS PROGRAMMING Press PROG push-button of RWL-01 After 5 seconds LED red diode switches on Release the push-button in RWL-01 device for a longer time. (signal pulsates) and then it switches off. - MEMORY IS DELETED MONOSTABLE mode: COOPERATION AND OPERATION RANGE Symbol ROP-01 ROP-02 ROB-01 SRP-02 SRP-03 RWG-01 RWL-01 ROM-01 ROM-10 RDP-01 RTN-01 RNK-02 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m Press transmitters Press PROG push-button of RWL-01 device Release transmitters Press the same transmitters push- RNK-04 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m push-button for a for a longer time until LED red diode switches on push-button. LED red diode -button and release it. LED red dio- P-256/8 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m longer time. (constant signal). Next release PROG push-button. switches on (first signal de switches on (the signal pulsates) P-257/4 (2) 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m pulsates, next the signal is and next the signal switches off - constant). THE TRANSMITTER IS ADDED. RNM-10 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m BISTABLE mode: RNP-01 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m RNP-02 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m RNL-01 160 m 180 m 180 m lack* lack* 200 m 160 m 200 m 200 m 160 m 200 m RTN-01 200 m 200 m 200 m 200 m 200 m 250 m 200 m 250 m 250 m 200 m 250 m RCR-01 160 m 180 m 180 m lack* lack* 200 m 160 m 200 m 200 m 160 m 200 m RTI-01 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m RXM-01 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m Press PROG push-button of RWL-01 device Press the transmitters push-button Release transmitters push-button. * - 1-channel transmitters do not cooperate with roller blinds controllers. for a longer time until LED red diode switches on for a longer time. LED red diode switches LED red diode switches on (the CAUTION: The given range concerns open area - an ideal condition without any natural or artificial obstacles. If there are some obstacles between a transmitter and a receiver, (constant signal). Next release PROG push-button. on (first signal pulsates, next the signal is signal pulsates), next the LED red it is advisable to decrease the range according to: wood and plaster - from 5 to 20, bricks - from 10 to 40 %, reinforced concrete - from 40 to 80 %, metal - from 90 to 100%, constant). diode switches off - it means the glass - from 10 to 20 %. Over- and underground medium and high electrical power lines, radio and television transmitters, GSM transmitters set close to a device system have also a negative influence on the range. TRANSMITTER IS ADDED. SWITCH ON/SWITCH OFF mode (two push-buttons): TRANSMITTERS RECEIVERS RNK-02 RNL-01 ROP-01 RWL-01 2channel button Radio foot 1-channel Radio lighting radio transmitter transmitter radio receiver switch RNK-04 RTI-01 ROP-02 RWG-01 4-channel button IR/EXTA FREE 2-channel Remote control radio transmitter transceiver radio receiver socket Press PROG push-button of RWL-01 device Press and release transmitters push- Press and release the second transmitters for a longer time until LED red diode switches on button. LED red diode switches on push-button. LED red diode switches on P-256/8 RNM-10 RDP-01 SRP-02 (constant signal). Next release PROG push-button. (first signal pulsates, next the signal is (the signal pulsates) and next it switches 8-channel 4-channel radio 1-channel Radio constant). off - THE TRANSMITTER IS ADDED. remote controller modular transmitter radio dimmer roller blinds controller TIME MODE (one push-button): P-257/4 RNP-01 ROB-01/12-24V SRP-03 4-channel 4-channel Radio Central radio remote controller radio transmitter gate controller roller blinds controller P-257/2 RNP-02 ROM-01 ROM-10 2-channel 4-channel 1-channel 2-channel radio remote controller radio transmitter radio modular receiver modular receiver RCR-01 RXM-01 Press PROG push-button of RWL-01 device Press and release transmitters push- Press and release the same transmitters Radio Translator for a longer time till LED red diode switches on button. LED red diode switches on push-button. LED red diode switches on motion sensor RS-485/EXTA FREE (constant signal). Next release PROG push-button. (the signal pulsates, next the signal is (the signal pulsates) and next it switches constant). off - THE TRANSMITTER IS ADDED. ACCESSORIES An exemplary programming procedure with the use of P-257/2 remote controller. The procedure for the rest of radio EXTA FREE ANT-01 RTN-01 transmitters is analogous. External Retransmitter antenna CAUTION: Every transmitter can cooperate with RWL-01 in a different mode, depending on how they were added to the device. One transmitter can be added during one programming cycle. Full memory is signalled with pulsating LED red diode. VER. 005 20.06.2011