Technical Information PrimeSTACK 2PS06017E32G28213 Preliminary data Key data 1x 325A AC at 690V AC, forced air (fan not implemented) General information Stacks for various inverter application. Semiconductors, heat sinks, drivers and sensors included. These are only technical data Please read carefully the complete documentation and maintain the proper design environment Especially note the EMC environment and the controller s functionality. Topology 1/2 B2I Application / Modulation Inverter / Sine Load type resistive, inductive Cooling forced air (fan not implemented) Market common industrial, drives, power supply Implemented sensors current, temperature Semicond. none (Unit 1) DC Link none Semicond. IGBT 2x FF300R17KE3 (Unit 2) Driver signals IGBT electrical CMOS Standards EN50178, UL94, prepared for UL508C Internal ID 28213 Mechanical drawing number 38000028 Electrical drawing number 2PS-C2-V prepared by: OW date of publication: 2013-05-03 approved by: AR revision: 2.0 1Technical Information PrimeSTACK 2PS06017E32G28213 Preliminary data Notes Overvoltage shutdown: It must be realized by the customer. Overvoltage and Overcurrent shutdown reaction time: This parameter refers to the customers controller. Electrical data DC Link min typ max units Voltage V 1100 1200 V DC Unit 2 AC min typ max units Voltage V 690 V Unit2 RMS V = 690V , V = 1100V, T = 40C, Unit2 RMS DC inlet Continuous current TJ 125C, fUnit2 = 50Hz, fsw2 = 2000Hz, IUnit2 325 ARMS cos(phi) = 0,85 Continuous current overload Tinlet = 40C, for overload capability 150% for 60s 231 ARMS cap. Short time current Tinlet = 40C, 10s, every 180s, initial load = 283ARMS IUnit2 354 ARMS DC current no rotating field, Tinlet = 40C IUnit2 DC 162,0 Aav Overcurrent shutdown within 15s 930 Apeak Switching frequency fsw2 20000 Hz V = 690V, V = 1100V, T = 40C, Unit2 DC inlet Power losses T 125C, f = 50Hz, f = 2000Hz, P 3770 W J Unit2 sw2 loss2 cos(phi) = 0,85, IUnit2 = 325ARMS Power factor cos(phi) -1,00 1,00 Unit2 General data min typ max units Power losses Ploss aux 40 W (PCB) power V 2 kV Burst according to IEC61800-3 at named EMC test control V 1 kV Burst interfaces aux (24V) VSurge 1 kV Insulation management is V 690 V Line RMS designed for Insulation test voltage according to EN50178, f = 50Hz, t = 60s V 2,5 kV isol RMS Controller interface data min typ max units Auxiliary voltage Vaux 18 24 30 Vav Auxiliary power requirement V = 24V P 40 W aux av aux Driver and interface board see separate technical information DR240 EiceDRIVER Driver core 2ED300C17-S resistor to GND 10,0k, capacitor to GND 1nF, high = Digital input level V 0,0 15,0 V in on, min 15mA Digital output level open collector, low = ok, max 15mA V 0,0 30,0 V out Analog current outputs Unit 2 load max 1mA at 325A V 3,43 3,50 3,60 V ana out Analog temperature output load max 1mA at T = 77C correspond to T = 125C V 8,90 9,10 9,30 V NTC j T out Overcurrent shutdown after overcurrent message by PrimeSTACK interface 10 s reaction time prepared by: OW date of publication: 2013-05-03 approved by: AR revision: 2.0 2