AC Line Monitor Logic-Out Device MID400 Description The MID400 is an optically isolated AC linetologic interface device. It is packaged in an 8lead plastic DIP. The AC line voltage is www.onsemi.com monitored by two backtoback GaAs LED diodes in series with an external resistor. A high gain detector circuit senses the LED current and drives the output gate to a logic low condition. PDIP8 6.6x3.81, 2.54P The MID400 has been designed solely for the use as an AC line 8 CASE 646BW monitor. It is recommended for use in any ACtoDC control 1 application where excellent optical isolation, solid state reliability, TTL compatibility, small size, low power, and low frequency PDIP8 9.655x6.6, 2.54P operations are required. CASE 646CQ 8 1 Features Direct Operation from any Line Voltage with the Use of an External PDIP8 GW 8 Resistor CASE 709AC 1 Externally Adjustable Time Delay Externally Adjustable AC Voltage Sensing Level MARKING DIAGRAM Logic Level Compatibility Safety and Regulatory Approvals: UL1577, 2,500 VAC for 1 Minute ON RMS MID400 DINEN/IEC6074755, 630 V Peak Working Insulation Voltage VXXYYT1 Applications MID400 = Specific Device Code Monitoring of the AC/DC Linedown Condition V = DIN EN/IEC6074755 Option (only appears on component ordered with Closedloop Interface between Electromechanical Elements such this option) as Solenoids, Relay Contacts, Small Motors, and Microprocessors XX = TwoDigit Year Code, e.g., 06 Time Delay Isolation Switch YY = Digit Work Week, Ranging from 01 to 53 T1 = Assembly Package Code FUNCTIONAL SCHEMATIC 1 8V CC N/C 2 7 AUX 3 6 V O N/C 4 5 GND ORDERING INFORMATION See detailed ordering and shipping information on page 8 of this data sheet. Semiconductor Components Industries, LLC, 2005 1 Publication Order Number: April, 2021 Rev. 2 MID400/DMID400 SAFETY AND INSULATION RATINGS (As per DIN EN/IEC 6074755, this optocoupler is suitable for safe electrical insulation only within the safety limit data. Compliance with the safety ratings shall be ensured by means of protective circuits.) Parameter Characteristics Installation Classifications per DIN VDE 0110/1.89 Table 1, For Rated Mains Voltage <150 V IIV RMS <300 V IIV RMS Climatic Classification 55/100/21 Pollution Degree (DIN VDE 0110/1.89) 2 Comparative Tracking Index 175 Symbol Parameter Value Unit V InputtoOutput Test Voltage, Method A, V x 1.6 = V , Type and Sample Test 1008 V PR IORM PR peak with t = 10 s, Partial Discharge < 5 pC m InputtoOutput Test Voltage, Method B, V x 1.875 = V , 100% Production Test 1182 V IORM PR peak with t = 1 s, Partial Discharge < 5 pC m V Maximum Working Insulation Voltage 630 V IORM peak V Highest Allowable OverVoltage 6000 V IOTM peak External Creepage 7 mm External Clearance 7 mm DTI Distance Through Insulation (Insulation Thickness) 0.4 mm T Case Temperature (Note 1) 150 C S I Input Current (Note 1) 60 mA S,INPUT P Output Power (Note 1) 150 mW S,OUTPUT 9 R Insulation Resistance at T , V = 500 V (Note 1) >10 IO S IO 1. Safety limit values maximum values allowed in the event of a failure. ABSOLUTE MAXIMUM RATINGS Symbol Parameter Value Unit T Storage Temperature 55 to +125 C STG T Operating Temperature 40 to +85 C OPR T Junction Temperature 55 to +100 C J T Lead Solder Temperature 260 for 10 seconds C SOL P Total Device Power Dissipation T = 25C 115 mW D A Derate Above 70C 4 mW/C EMITTER RMS Current 25 mA DC Current 30 mA P LED Power Dissipation T = 25C 45 mW D(EMITTER) A Derate Above 70C 2 mW/C DETECTOR I Low Level Output Current 20 mA OL V High Level Output Voltage 7 V OH V Supply Voltage 7 V CC P Detector Power Dissipation T = 25C 70 mW D(DETECTOR) A Derate Above 70C 2 mW/C Stresses exceeding those listed in the Maximum Ratings table may damage the device. If any of these limits are exceeded, device functionality should not be assumed, damage may occur and reliability may be affected. www.onsemi.com 2