NTD3055L104, NTDV3055L104 Power MOSFET 12 A, 60 V, Logic Level NChannel DPAK/IPAK Designed for low voltage, high speed switching applications in NTD3055L104, NTDV3055L104 ELECTRICAL CHARACTERISTICS (T = 25C unless otherwise noted) J Characteristic Symbol Min Typ Max Unit OFF CHARACTERISTICS DraintoSource Breakdown Voltage (Note 3) V Vdc (BR)DSS (V = 0 Vdc, I = 250 Adc) 60 70 GS D Temperature Coefficient (Positive) 62.9 mV/C Zero Gate Voltage Drain Current I Adc DSS (V = 60 Vdc, V = 0 Vdc) 1.0 DS GS (V = 60 Vdc, V = 0 Vdc, T = 150C) 10 DS GS J GateBody Leakage Current (V = 15 Vdc, V = 0 Vdc) I 100 nAdc GS DS GSS ON CHARACTERISTICS (Note 3) Gate Threshold Voltage (Note 3) V Vdc GS(th) (V = V , I = 250 Adc) 1.0 1.6 2.0 DS GS D 4.2 mV/C Threshold Temperature Coefficient (Negative) Static DraintoSource OnResistance (Note 3) R m DS(on) (V = 5.0 Vdc, I = 6.0 Adc) 89 104 GS D Static DraintoSource OnVoltage (Note 3) V Vdc DS(on) (V = 5.0 Vdc, I = 12 Adc) 0.98 1.50 GS D (V = 5.0 Vdc, I = 6.0 Adc, T = 150C) 0.86 GS D J Forward Transconductance (Note 3) (V = 8.0 Vdc, I = 6.0 Adc) g 9.1 mhos DS D FS DYNAMIC CHARACTERISTICS Input Capacitance C 316 440 pF iss (V = 25 Vdc, V = 0 Vdc, DS GS Output Capacitance C 105 150 oss f = 1.0 MHz) Transfer Capacitance C 35 70 rss SWITCHING CHARACTERISTICS (Note 4) TurnOn Delay Time t 9.2 20 ns d(on) Rise Time t 104 210 (V = 30 Vdc, I = 12 Adc, r DD D V = 5.0 Vdc, R = 9.1 ) (Note 3) TurnOff Delay Time GS G t 19 40 d(off) Fall Time t 40.5 80 f Gate Charge Q 7.4 20 nC T (V = 48 Vdc, I = 12 Adc, DS D Q 2.0 1 V = 5.0 Vdc) (Note 3) GS Q 4.0 2 SOURCEDRAIN DIODE CHARACTERISTICS Forward OnVoltage (I = 12 Adc, V = 0 Vdc) (Note 3) V 0.95 1.2 Vdc S GS SD (I = 12 Adc, V = 0 Vdc, T = 150C) 0.82 S GS J Reverse Recovery Time t 35 ns rr (I = 12 Adc, V = 0 Vdc, S GS t 21 a dI /dt = 100 A/ s) (Note 3) S t 14 b Reverse Recovery Stored Charge Q 0.04 C RR Product parametric performance is indicated in the Electrical Characteristics for the listed test conditions, unless otherwise noted. Product performance may not be indicated by the Electrical Characteristics if operated under different conditions. 3. Pulse Test: Pulse Width 300 s, Duty Cycle 2%. 4. Switching characteristics are independent of operating junction temperatures.