175W Single Output MINT1175 Family Medical Grade FEATURES AND BENEFITS Medical rd 2 x 4 x 1.3 Package Approved to CSA/EN/IEC/UL60601-1, 3 Edition For 1U Applications 2 x MOPP Isolation Class I and Class II Versions 12V Fan Output 175W w/air, 120W Convection Cooled Efficiency 90% Typical at Full Load Universal Input 90VAC264VAC 3 Year Warranty Average Efficiency meets Level V Requirements RoHS Compliant MODEL SELECTION Output Current Fan Ripple & Total OVP Model Number Volts Output Noise Regulation Threshold w/200LFM air Convection 0.5%RMS, MINT1175A1206K01 12V 14.6A 10.0A 12Vdc/0.4A 3% 14.0 1.1V 1.2% pk-pk 0.5%RMS, MINT1175A1506K01 15V 11.7A 8.0A 12Vdc/0.4A 3% 19.5 1.5V 1.0% pk-pk 0.5%RMS, MINT1175A2406K01 24V 7.3A 5.0A 12Vdc/0.4A 3% 28.0 2.5V 1.2% pk-pk 0.5%RMS, MINT1175A4806K01 48V 3.6A 2.5 A 12Vdc/0.4A 3% 55.0 4.0V 1.0% pk-pk 0.5%RMS, MINT1175A5606K01 56V 3.1A 2.1A 12Vdc/0.4A 3% 59.0 1.0V 1.0% pk-pk Notes: 1. * Total convection power is 120 Watts. 2. ** Measured with noise probe directly across output terminals, and load terminated with 0.1F ceramic and 10F low ESR capacitors. 3. *** Output adjustment on 56V model will not exceed 56.2 volts Page 1 MINT1175 Datasheet v0919 Copyright 2019 SL Power Electronics Corp. All rights reserved.175W Single Output MINT1175 Family Medical Grade INPUT OUTPUT 100VAC240VAC, 10%, 47Hz63Hz, 1, See chart Output Voltage AC Input 120Vdc370Vdc 175W continuous, with 200 lfm airflow, 120W 115VAC: 2A, 230VAC: 1A Input Current convection cooled See chart for specific Output Power voltage model ratings. 264VAC, cold start: will not exceed 50A Inrush Current Less than 2sec. 115VAC (inversely proportional to Turn On Time F1, F2: 4A, 250VAC fuses provided on all models Input Fuses input voltage and thermistor temperature) <200A 264VAC, 60Hz, NC <400A SFC Earth Leakage Current 16mS, typical (120W output load) Hold-up Time 90% typical at 115VAC Efficiency See chart Ripple and Noise 3%. See chart Total Regulation PFC: Fixed, 65kHz. Main Converter: Variable 35kHz200kHz, Switching Frequency PROTECTION 65Hz70kHz at full load. Not required Minimum Load OVP firing reduces output voltage to <50% of Overvoltage Protection 50% load step. i/t: <0.2A/S nominal in <50mS. See chart for trip range. Transient Response Max Volt Deviation = 3% Provided - no damage will occur if the output Short Circuit Protection is shorted. 5% from nominal Voltage Adjustability Hiccup Mode Overload Protection AUXILIARY SIGNALS ISOLATION Open collector logic signal goes and stays Input-Output: 4000VAC, 2 x MOPP HIGH 100mS to 500mS after main output DC OK Input-Ground: 1800VAC, 1 x MOPP Isolation reaches regulation Output-Ground: 1500VAC During normal operation, stays HIGH. Signal goes LOW with 5mS warning before loss of AC Power Fail DC output from AC failure Connect to inhibit pin to output common to Inhibit inhibit the DC output RELIABILITY 331,000 hours, 25C Ambient, 110VAC input MTBF SAFETY rd EN/CSA/UL/IEC 60601-1, 3 Edition Safety Standards Page 2 MINT1175 Datasheet v0919 Copyright 2019 SL Power Electronics Corp. All rights reserved.