ACS302 3-line overvoltage protected AC switch array Datasheet - production data Description ACS302 offers 3 AC switches in one single package with 600 V blocking voltage, high commutation and noise immunity - all that is required for inductive load control. Its high integration allows reduced space consumption of PCB. ACS302 enables inductive application to be compliant with IEC 61000-4-4 and IEC 61000-4-5. SO-20 ACS302-6T3 Figure 1. Pinout OUTPUT 1 COM 1 20 2 19 Pin 11 Features 3 18 GATE 1 4 17 3-line AC switch array OUTPUT 2 16 GATE 2 5 Overvoltage protection 6 15 Pin 1 High static immunity and dynamic commutation 7 14 Pins 2, 3, 4, 6, 7, 8, 10, GATE 3 8 13 and 19, 17, 15, 14, 12 V , V = 600 V DRM RRM OUTPUT 3 9 12 are not connected. T = 125 C max. 11 COM J 10 I < 5 mA GT Figure 2. Configuration Application Drive of low power highly inductive or resistive OUT1 OUT2 OUT3 loads like: ACS302 Relay, valve, solenoid Dispenser, door lock S1 S2 S3 Pump, fan, micro-motor Table 1. Device summary COM G1 G2 G3 Order code Package V , V I DRM RRM GT ACS302-6T3 SO-20 600 V 5 mA ACS is a registered trademark of STMicroelectronics July 2013 DocID024500 Rev 1 1/12 This is information on a product in full production. www.st.com 12Characteristics ACS302 1 Characteristics Table 2. Absolute maximum ratings for one switch and T = 25 C, unless otherwise specified J Symbol Parameter Value Unit 1 switch ON T = 110 C 0.2 A On-state rms current a I T(RMS) (180 conduction angle, full sine wave) 2 or 3 switches ON T = 90 C 0.4 A a t =16.7ms 7.6 p I Non repetitive surge peak on-state current (T initial = 25 C) A TSM J t = 20 ms 7.3 p 2 2 2 ItI t value for fusing t = 10ms 0.38 A s p Critical rate of rise of on-state current dI/dt F = 120 Hz 50 A/s I = 2 x I , t 100 ns G GT r V , V Repetitive peak off-state voltage T = 125 C 600 V DRM RRM j (1) V Non-repetitive line peak pulse voltage 2 kV pp I Peak gate current T = 125 C t = 20 s 1 A GM J p P Peak gate power T = 125 C t = 20 s 10 W GM J p P Average gate power dissipation 0.1 W G(AV) T Storage junction temperature range -40 to +150 C stg T Operating junction temperature range -40 to +125 C j T Maximum lead temperature for soldering during 10 s. 260 C L 1. According to test described by IEC 61000-4-5 standard and figure 3 Table 3. Electrical characteristics (for one switch and T = 25C, unless otherwise specified) j Symbol Test conditions Quadrants Value Unit MIN 0.25 I V = 12 V, R = 33 mA GT OUT L MAX 5 II - III V V = 12 V, R = 33 MAX 0.9 V GT OUT L V V = V , R = 3.3 k, T = 125 C II - III MIN 0.15 V GD OUT DRM L j I I = 100 mA, gate open MAX 20 mA H T I I = 1.2 I II - III MAX 25 mA L G GT dV/dt V = 400 V, gate open T = 125 C MIN 300 V/s OUT j (dI/dt)c (dV/dt)c = 15 V/s, turn-off time 20 ms T = 125 C MIN 0.15 A/ms j t I = 1 A, V = 400 V, I = 100 mA, dI /dt = 100 mA/s, R = 400 TYP 2 s gt TM D G G L V I = 0.1 mA, t = 1 ms MIN 650 V CL CL p 2/12 DocID024500 Rev 1