4-CHANNEL RADIO TRANSMITTER RNP-02 MANUAL INSTRUCTION ZAMEL Sp. z o.o. ul. Zielona 27, 43-200 Pszczyna, Poland tel. +48 (32) 210 46 65, fax +48 (32) 210 80 04 www.zamelcet.com, e-mail: marketing zamel.pl TECHNICAL DATA DESCRIPTION Radio transmitter RNP-02 realises RNP-02 remote control function of devices. It is mounted in a junction box and under Input rated voltage: 3 V DC the existing switch (monostable push- Battery type: CR2032 buttons). This solution is very useful and Battery life: 3 5 years (dependent on use) results in easy installation of EXTA FREE Release terminals: IN1, IN2, IN3, IN4 (no voltage) system without interference in existing Number of channels: 4 wiring system. There is a possibility of us- ing electroinstallation equipment of any Transmission: radio 868,32 MHz manufacturer (no design limit). Transmission way: unidirectional Coding: addressing transmission Range: up to 200 m in the open area Optic signalling of transmission/battery discharge: LED red diode FEATURES o Ambient temperature range -10 +55 C radio transmitter mounted in 60 mm Number of terminal clamps: 6 junction box, 2 Section f connecting cables: 1 mm battery powered, Operating position: free possibility of connection to a traditional, existing household switch, Casing mounting: installation cable box 60 mm four release inputs (no voltage), Casing protection degree: IP20 (EN 60529) possibility of independent control of four Protection level: II receivers, Overvoltage category: II wide range of operation (up to 200 m), Pollution degree: 2 possibility of simultaneous switching on/switching off any number of EXTA Dimensions: 47,5 x 47,5 x 13 mm FREE system receivers, Weight: 0,023 kg possibility of increasing operation range Reference standard: ETSI EN 300 220-1, by means of RTN-01 retransmitter. ETSI EN 300 220-2 APPEARANCE Input release wires (IN1, IN2, IN3, IN4) Output release wires (COM) Optic signalling of receivers operation The symbol means selective collecting of electrical and electronic equipment. It is forbidden to put the used equipment together with other waste. VER. 003 20.05.2011CONNECTION MOUNTING, CONNECTION 1. Disconnect power supply by the phase fuse, the circuit-breaker or the switch-disconnector combined to the proper circuit. 2. Check if there is no voltage on connection ca- bles by means of a special measure equipment. 3. Secure 230V AC installation wires by means of a terminal block or insulating tape. 4. Connect the existing switch to RNP-02 in ac- cordance with the installing diagram. 5. Install RNP-02 device in installation cable box. The ZAMEL company devices which are characterised The device is ready to operate after cor- with this sign can cooperate rect mounting and connection. Releasing with each other. the system by a monostable push-button connected to one of four release terminals (IN1-IN4) causes the RNP-02 device to send APPLICATION a radio control signal added to this input (channel). LED red diode signals the trans- mission is on. Device programming pro- 4-channel radio transmitter cedure (adding a transmitter to receivers RNP-02 controls operation of 2-channel radio flush receiver memory) is described in manual instructions ROP-02 (switch on/switch of particular EXTA FREE receivers. off, time switch off) or remote control socket RWG-01 BATTERY CHANGE (switch on/switch off). RNP-02 Battery discharge status is signalled by a sev- device can be mounted under the existing lighting switch. It eral flashes of LED red diode during trans- does not demand connection of mission time. 230V AC power supply. 1. Unscrew two screws from the bottom trans- mitters cover. 2. Remove the printed-circuit board. 3. Remove the battery from the latch by means of a screwdriver . 4. Place a new battery. Watch battery polari- sation marked on the latch. Wrong battery mounting may cause device damage. 5. Put the removed printed-circuit board back in the base and screw the bottom cover. COOPERATION AND OPERATING RANGE Symbol ROP-01 ROP-02 ROB-01 SRP-02 SRP-03 RWG-01 RWL-01 ROM-01 ROM-10 RDP-01 RTN-01 RNK-02 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m RNK-04 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m P-256/8 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m P-257/4 (2) 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m RNM-10 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m RNP-01 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m RNP-02 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m RNL-01 160 m 180 m 180 m lack* lack* 200 m 160 m 200 m 200 m 160 m 200 m RTN-01 200 m 200 m 200 m 200 m 200 m 250 m 200 m 250 m 250 m 200 m 250 m RCR-01 160 m 180 m 180 m lack* lack* 200 m 160 m 200 m 200 m 160 m 200 m RTI-01 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m RXM-01 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m *- 1-channel transmitters do not cooperate with roller blind controllers. CAUTION: The given range concerns open area - an ideal condition without any natural or artificial obstacles. If there are some obstacles between a transmitter and a receiver, it is advisable to decrease the range according to: wood and plaster - from 5 to 20, bricks - from 10 to 40 %, reinforced concrete - from 40 to 80 %, metal - from 90 to 100%, glass - from 10 to 20 %. Over- and underground medium and high electrical power lines, radio and television transmitters, GSM transmitters set close to a device system have also a negative influence on the range. WARRANTY CARD There is 24 months guarantee on the product 1. ZAMEL provides a two-year warranty for its products. 2. The ZAMEL warranty does not cover: a) mechanical defects resulting from transport, loading / unloading or other circumstances b) defects resulting from incorrect installation or operation of ZAMEL products c) defects resulting from any changes made by CUS- TOMERS or third parties, to products sold or equipment necessary for the correct operation of products sold d) defects resulting from force majeure or other aleatory events for which ZAMEL is not liable e) power supply (batteries) to be equipped with a device in the moment of sale (if they appear) 3. All complaints in relation to the warranty must be provided by the CUSTOMER in writing to the retailer after discovering a defect. 4. ZAMEL will review complaints in accordance with existing regulations. 5. The way a complaint is settled, e.g. replacement of the product, repair or refund, is left to the discretion of ZAMEL. 6. Guarantee does not exclude, does not limit, nor does it suspend the rights of the PURCHASER resulting from the discrepancy between the goods and the contract. Salesman stamp and signature, date of sale VER. 003 20.05.2011