RWG-01/K REMOTE CONTROL SOCKET WITH P-257/2 REMOTE CONTROLER P-257/2 OPERAAPPLICATION TION CAPACITY MANUAL INSTRUCTION After pressing the push-button the remote control sends a signal on 868,32 MHz which 2000 W AC5b controls EXTA FREE receivers. Device programming procedure (adding a transmit- ter to the transmitters memory) is described in manual instruction of particular EXTA FREE system receivers. The range (up to 250 m depending on a receiver) can 1000 W AC5a be changed by means of a retransmitter or few RTN-01 retransmitters. ZAMEL Sp. z o.o. 750 W AC5a BATTERY CHANGE Battery discharge status is signalled by several LED red diode flashes during ul. Zielona 27, 43-200 Pszczyna, Poland 500 W AC5a transmission time. tel. +48 (32) 210 46 65, fax +48 (32) 210 80 04 www.zamelcet.com, e-mail: marketing zamel.pl 1. Remove the screws from the bottom part of the remote control. 2. Remove the upper cover with the silicon keyboard. 3. Remove the battery from the latch. SERIA F DESCRIPTION TECHNICAL DATA 4. Mount a new battery. Watch battery polarisation marked on the latch. Wrong bat- tery mounting may cause device damage. P-257/2 RWG-01 Remote control socket RWG-01 is 5. Place back the top cover with the keyboard and tighten the screws. Input rated voltage: 3 V (battery CR2032) 230 V~ used to connect any 230 V AC rece- Battery life 3 5 years - iver of 4000 VA and to wireless control CAUTION: While changing the battery, it is suggested to press any of the buttons Input voltage tolerance: - -15 +10 % by means of different EXTA FREE sys- for about 5 seconds before putting it into a latch. Next press transmission button Nominal frequency: - 50 / 60 Hz tem transmitters. The device can be The ZAMEL company devices several times to check its operation. If the transmitter does not work properly re- Nominal power consumption: - 0,29 W mounted without any additional tools which are characterised peat the battery change procedure. with this sign can cooperate or interference in existing wiring - it is Optic signalling of power supply: - LED green diode with each other. directly mounted to 230 V AC socket. Number of operation modes: - 5 Number of channels: 2 1 Transmission: radio 868,32 MHz APPLICATION Coding way: unidirectional Coding: addressing transmission FEATURES Maximum number of transmitters: - 32 P-257/2 2-channel remote Range: up to 250 m in the open area up to 300 m in the open area control operates as a cooperation with wireless EXTA transmitter of remote Time adjustment: - 1 sec. 18 hours (every sec.) FREE system transmitters (it is ob- control socket RWG-01 Optic signalling of device operation: LED red diode ligatory to purchase it separately), and of radio receiver Relay contact parameters: - 1NO 16A / 250V~ AC1 4000 VA P-257/2 remote cotrol included, ROP-01. RNK-02 radio o Ambient temperature range: -10 +55 C lighting, heating control and other button transmitter and Operating position: free receivers control, RWL-01 radio lighting switch are also devices of easy mounting in 230V AC socket, Casing mounting: - 230 V~ socket EXTA FREE system. five operation modes: switching on Casing protection degree: IP20 (EN 60529) mode, switching off, monostable, Protection level: III II bistable, time (switch off delay), Overvoltage category: - II wide range of operation (up to 250 m), Pollution degree: 2 radio transmission and relay status Surge voltage: - 1 kV (EN 61000-4-5) are optically signalled, Dimensions: 74 x 33 x 11,5 mm 160 x 66 x 90 mm low current consumption, possibil- Weight: 0,020 kg 0,160 kg ity of constant work Reference standard: ETSI EN 300 220-1 EN 60669, EN 60950 possibility of widening operation ETSI EN 300 220-2 EN 61000 range by means of RTN-01 re- transmitter. APPEARANCE The device is designed for single-phase instal- lation and must be in- stalled in accordance Optic signalling Antenna with standards valid in a of transmitters operation particular country. The de- Push-buttons vice should be connected CAUTION according to the details in- Optic signalling cluded in this operating manual. Installation, of input voltage connection and control should be carried out by a qualified electrician staff, who act in ac - Optic signalling of cordance with the service manual and the transmitters switching on device functions. In case of casing dismantling an electric Programming push-button shock may occur, and the guarantee is lost then. Before installation make sure the con- WARRANTY CARD nection cables are not under voltage. The cruciform head screwdriver 3,5 mm should be used to instal the device. Improper trans- There is 24 months guarantee on the product Receivers socket port, storage, and use of the device inufl ence 1. ZAMEL provides a two-year warranty for its products. its wrong functioning. It is not advisable to in- 2. The ZAMEL warranty does not cover: a) mechanical defects resulting from transport, loading / unloading or other circumstances b) defects resulting from incorrect installation or operation of ZAMEL products c) defects resulting from any changes made by CUS- stal the device in the following cases: if any TOMERS or third parties, to products sold or equipment necessary for the correct operation of products sold d) defects resulting device part is missing or the device is dam- Power supply plug from force majeure or other aleatory events for which ZAMEL is not liable e) power supply (batteries) to be equipped with a device aged or deformed. In case of improper func- in the moment of sale (if they appear) tioning of the device contact the producer. 3. All complaints in relation to the warranty must be provided by the CUSTOMER in writing to the retailer after discovering a defect. The symbol means selective 4. ZAMEL will review complaints in accordance with existing regulations. collecting of electrical and electronic 5. The way a complaint is settled, e.g. replacement of the product, repair or refund, is left to the discretion of ZAMEL. 6. Guarantee does not exclude, does not limit, nor does it suspend the rights of the PURCHASER resulting from the discrepancy equipment. between the goods and the contract. It is forbidden to put the used equipment together with other waste. Salesman stamp and signature, date of sale VER. 005 11.07.2011OPERATION TIME PROGRAMMING The device can operate in five modes: 1s 2s ns MONOSTABLE BISTABLE SWITCH ON TIME the relay operates only (one push-button) the the device switches on the device switches while pressing transmit- device changes relay after pressing the push- off according to the ters push-button. status cyclically always button. adjusted time (tp), after pressing the same push- SWITCH OFF but it may be switched off before Press PROG push-button of RWG-01 device for a longer time till Press PROG push-button of RWG-01 device After the adjusted time is button. the device switches off adjusted time finishes. Default LED red diode switches on (constant signal). Next release PROG and then release it. LED red diode switches finished (the number of LED after pressing the push- settings - 15 seconds. push-button. Wait (for about 5 seconds) till LED red diode switches off and then switches on (signal pulsates). red diode flashes) press button. on (first signal pulsates, next the signal is constant). Every LED diode pulse equals 1 second. PROG push-button and then CAUTION Adjusted time can- release it - TIME IS ADDED. not be deleted. Maximum time is 18 hours. RADIO TRANSMITTERS DELETION RADIO TRANSMITTERS PROGRAMMING Press PROG push-button of RWG-01 After 5 seconds LED red diode switches on Release the push-button in RWG-01 device for a longer time. (signal pulsates) and then it switches off. - MEMORY IS DELETED. MONOSTABLE mode: COOPERATION AND OPERATING RANGE Symbol ROP-01 ROP-02 ROB-01 SRP-02 SRP-03 RWG-01 RWL-01 ROM-01 ROM-10 RDP-01 RTN-01 RNK-02 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m Press transmitters Press PROG push-button of RWG-01 device Release transmitters push- RNK-04 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m Press the same transmitters push- push-button for for a longer time until LED red diode switches on button. LED red diode switches -button and release it. LED red diode P-256/8 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m a longer time. (constant signal). Next release PROG push-button. on (first signal pulsates, next switches on (the signal pulsates) and P-257/4 (2) 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m the signal is constant). next it switches off - THE TRANS- RNM-10 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m MITTER IS ADDED. RNP-01 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m BISTABLE mode: RNP-02 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m RNL-01 160 m 180 m 180 m lack* lack* 200 m 160 m 200 m 200 m 160 m 200 m RTN-01 200 m 200 m 200 m 200 m 200 m 250 m 200 m 250 m 250 m 200 m 250 m RCR-01 160 m 180 m 180 m lack* lack* 200 m 160 m 200 m 200 m 160 m 200 m RTI-01 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m RXM-01 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m Press PROG push-button of RWG-01 device Press the transmitters push-button Release transmitters push-button. LED * - 1-channel transmitters do not cooperate with roller blind controllers. for a longer time until LED red diode switches on for a longer time. LED red diode switches on red diode switches on (the signal pulsates), CAUTION: The given range concerns open area - an ideal condition without any natural or artificial obstacles. If there are some obstacles between a transmitter and a receiver, (constant signal). Next release PROG push-button. (first signal pulsates, next the signal is constant). next the LED red diode switches off - it it is advisable to decrease the range according to: wood and plaster: from 5 to 20 %, bricks: from 10 to 40 %, reinforced concrete: from 40 to 80 %, metal: from 90 to 100% , glass: from 10 to 20 %. means the TRANSMITTER IS ADDED. Over- and underground medium and high electrical power lines, radio and television transmitters, GSM transmitters set close to a device system have also a negative influence on the range. SWITCH ON/SWITCH OFF mode (two push-buttons): TRANSMITTERS RECEIVERS RNK-02 RNL-01 ROP-01 RWL-01 2channel button Radio 1-channel Radio lighting radio transmitter foot transmitter radio receiver switch RNK-04 RTI-01 ROP-02 RWG-01 4-channel button IR/EXTA FREE 2-channel Remote control Press PROG push-button of RWG-01 device Press and release transmitters first push- Press and release the second transmitters radio transmitter transceiver radio receiver socket for a longer time until LED red diode switches on button. LED red diode switches on (first push-button. LED red diode switches on (constant signal). Next release PROG push-button. signal pulsates, next the signal is constant). (the signal pulsates) and next it switches P-256/8 RNM-10 RDP-01 SRP-02 off - THE TRANSMITTER IS ADDED. 8-channel 4-channel radio 1-channel Radio roller blinds remote control modular transmitter radio dimmer controller TIME mode (one push-button): P-257/4 RNP-01 ROB-01/12-24V SRP-03 4-channel 4-channel Radio Central radio roller remote control radio transmitter gate controller blinds controller P-257/2 RNP-02 ROM-01 ROM-10 2-channel 4-channel 1-channel radio 2-channel remote control radio transmitter modular receiver radio modular receiver Press PROG push-button of RWG-01 device Press the transmitters push-button and then Press and release the same transmitters RCR-01 RXM-01 for a longer time till LED red diode switches on release it. LED red diode switches on push-button. LED red diode switches on Radio RS-485/EXTA FREE (constant signal). Next release PROG push-button. (first signal pulsates, next the signal is constant). (signal pulsates) and then switches off - motion sensor Transceiver THE TRANSMITTER IS ADDED. ACCESSORIES An exemplary programming procedure with the use of P-257/2 remote control. The procedure for the rest of radio EXTA FREE transmitters is analogous. CAUTION: Every transmitter can cooperate with RWG-01 in a different mode, depending on how they were added to ANT-01 RTN-01 the device. One transmitter can be added during one programming cycle. Full memory is signalled with pulsating LED red diode. External antenna Retransmitter VER. 005 11.07.2011