WWW.PHIHONG.COM 8/16/24 Port Gigabit Power over Ethernet Midspan POE370U for 10/100/1000 Base-T Networks Features IEEE 802.3af Detection, Disconnect and Full Power of 370W--15.4W per Port No Overload Protection Power Management required NIC Interface (Optional) Full Protection OTP, OCP, OVP SSL Option with SNMPv3 48V RPS Input (Optional) 10/100/1000 base T Compatible Cisco Legacy Detection Limited Lifetime Warranty 1U Rack Mounting Kit Ships with Unit Applications VoIP Phones Security Systems Access Point Lighting Systems with Single UPS Safety Approvals cUL/UL SAA CE C-Tick Mechanical Characteristics Length: 438mm (17.25in) Height: 44.5 mm (1.75in) Width: 228mm (8.98in) Weight: 3.8Kg (8.5lbs) Output Specifications Maximum Output Model Number of Ports Power POE370U-480-8(x)* 8 125W POE370U-480-16(x)* 16 250W POE370U-480-24(x)* 24 370W *Optional code (x) = Blank for standard product with no options N includes SNMP, Simple Network Management Protocol R RPS DC Input RN for RPS input and SNMP Phihong is not responsible for any error, and reserves the right to make changes without notice. Please visit our website at www.phihong.com for the most up-to-date specifications and contact information. Revision 3/2/2015 POE370U Characteristics WWW.PHIHONG.COM Isolation Test INPUT: Primary to Secondary: 4242VDC for 1 minute AC Input Voltage Range Primary to Ground: 2121VDC for 1 minute 90 to 264VAC Secondary to Ground: 2121VDC for 1 minute AC Input Voltage Rating Immunity EN50082-1 100 to 240VAC ESD: EN61000-4-2. Level 3 RS: EN61000-4-3. Level 2 AC Input Current EFT: EN61000-4-4. Level 2 5.5A (RMS) maximum for 90VAC Surge: EN61000-4-5. Level 3 2.75A (RMS) maximum for 240VAC CS: EN61000-4-6. Level 2 Voltage Dips EN61000-4-11 Leakage Current Harmonic: EN61000-3-2 Class A 3.5mA maximum 254VAC 60Hz IEEE 802.3af Interoperability AC Input Frequency UNH Interoperability report available on request 47-63Hz FEATURE: AC Inrush Current Cisco Legacy detection 30A (RMS) maximum for 115VAC No extern parts required for Legacy devices: 60A (RMS) maximum for 230VAC VoIP Phones: 7910, 7912, 7940, 7960 OUTPUT: Access Points: Total Output Power 350, 1100, 1200 15.4W per port Over Voltage/Current, Short Circuit Protection Ripple and Regulation Outputs equipped with short circuit protection and 100mV maximum overload protection as per 802.3af specifications The output can be shorted permanently without damage Efficiency 75% (typical) at maximum load, and 120VAC 60Hz Over Temperature Protection Automatic shutdown without damage Hold-up Time 16mS min. 120VAC at maximum load Indicators Green LED: Power detected ON Transient O/P Voltage Protection Yellow LED: Fault detected 60V maximum at switch on and off at any AC line Phase USB Diagnostics Port Turn-On Delay Time USB B port for diagnostics and manual port control 3 sec maximum at maximum load, and 120VAC 60Hz, Windows GUI 25Hz Input Connector ENVIRONMENTAL: AC IEC320 inlet 3 pin Temperature DC for RPS option Operation 0 to +40C Molex Minifit Non-operation -25 to +65C Shell 39-01-20-65 Pins 39-00-0077 Humidity Operation 5 to 90% Warranty Non-Operation 5 to 90% Limited Lifetime Warranty EMC En55022 Class B, FCC Class B with FTP cabling EN55022 Class A, FCC Class A with UTP cabling