QPC3024 75 Absorptive High Isolation SPDT Switch Product Overview The QPC3024 is a 75 Silicon on Insulator (SOI) single-pole, double throw (SPDT) switch designed for use in CATV, satellite set top, and other high performance communications systems. It offers a high isolation symmetric topology with excellent linearity and power handling capability. No blocking caps are necessary on the RF ports. The design is non-reflective such that 16 Pad 4x4mm QFN Package RF ports 1 and 2 are terminated in in the off-state. The VEN pin allows for a terminated all-off state. Applying a negative voltage to the VNEG pin will turn the negative voltage generator Key Features off and allow for external supply input. 5MHz to 3000MHz Operation Symmetric SPDT Non-Reflective (RF1, RF2) Functional Block Diagram Terminated All-Off State No Blocking Caps Required Unless Voltage on RF Line High Isolation: >65dB at 1.2GHz High Input IP3: >60dBm Option to Turn Off Negative Voltage Generator and Supply VNEG Externally 2kV ESD +1.8V Logic Compatible Applications MDU Amplifiers Point To Point Optical Nodes Set Top Box PCTV Multi-tuner DVR Top View Ordering Information Part No. Description QPC3024SQ Sample bag with 25 pieces QPC3024SR 7 Reel with 100 pieces QPC3024TR13 13 Reel with 2500 pieces QPC3024PCK 53000MHz PCBA with 5 pc. sample bag Data Sheet Rev.C , December 28, 2016 Subject to change without notice - 1 of 14 - www.qorvo.com QPC3024 75 Absorptive High Isolation SPDT Switch Absolute Maximum Ratings Recommended Operating Conditions Parameter Rating Parameter Min Typ Max Units Control Voltage (V , V ) +6.0V Supply Voltage, V +2.7 +3 +5.5 V CTL EN DD Supply Voltage (V ) +6.0V Supply Voltage, V 5.5 5 3 V DD NEG External Negative Supply (V ) 6.0V Temperature Range 40 +105 C NEG Maximum CW Input Power at 25C +36dBm Electrical specifications are measured at specified test conditions. Specifications are not guaranteed over all recommended operating conditions. Maximum CW Input Power, Terminated Port +28dBm Junction Temperature +125C Storage Temperature Range 40 to +150C Exceeding any one or a combination of the Absolute Maximum Rating conditions may cause permanent damage to the device. Extended application of Absolute Maximum Rating conditions to the device may reduce device reliability. Electrical Specifications (1) Parameter Conditions Min Typ Max Units Frequency Range 5 3000 MHz 5MHz 0.38 50MHz 0.42 Insertion Loss 1.2GHz 0.82 dB 2GHz 0.83 3GHz 1.4 5MHz 75 50MHz 70 Isolation 1.2GHz 66 dB (RFC to RF1/RF2) 2GHz 66 3GHz 56 5MHz 75 50MHz 70 Isolation 1.2GHz 56 dB (RF1 to RF2) 2GHz 52 3GHz 45 5MHz 33 50MHz 32 Return Loss 1.2GHz 15 dB (RFC On-state) 2GHz 17 3GHz 13 5MHz 40 50MHz 39 Return Loss (RF1/RF2 Off-state) 1.2GHz 19 dB Terminated Ports 2GHz 18 3GHz 25 Notes: 1. Test Conditions Unless Otherwise Specified: T = +25C, V = 0/+5 V, V = +5V, 75 system. A CTL DD Data Sheet Rev.C , December 28, 2016 Subject to change without notice - 2 of 14 - www.qorvo.com