4-CHANNEL RADIO MODULAR TRANSMITTER RNM-10 MANUAL INSTRUCTION ZAMEL Sp. z o.o. ul. Zielona 27, 43-200 Pszczyna, Poland tel. +48 (32) 210 46 65, fax +48 (32) 210 80 04 www.zamelcet.com, e-mail: marketing zamel.pl TECHNICAL DATA DESCRIPTIoN RNM-10 4-channel radio modular transmitter RNM-10 cooperates with wireless EXTA Input (supply) terminals: L, N, L, N FREE system receivers. It is mounted on Input rated voltage: 230 V AC a TH-35 rail. The device has 4 independ- Input voltage tolerance: -15 +10 % ent inputs released by power supply volt- Nominal frequency: 50 / 60 Hz age 230V~. Installation connectors, wired Nominal power consumption: 0,35 W EXTA home automation devices or other Optic signalling of power supply: LED green diode relay devices (time programmers, motion Release terminals: IN1, IN2, IN3, IN4 sensors, programmable relays, etc.) can be Number of channels: 4 connected to RNM-10 release terminals. Transmission: radio 868,32 MHz RNM-10 application allows to integrate the Coding way: unidirectional above mentioned devices with EXTA FREE Coding: addressing transmission system receivers and allows for wireless Range: up to 300 m in the open area control of these devices. Optic signalling of transmission: LED red diode Optic signalling of input status: 4 x LED red diode o Ambient temperature range: -10 +55 C 2 Section of connecting cables: up to 2,5 mm FEATuRES Operating position: free Casing mounting: TH-35 rail (according to EN 60715) possibility of independent control of four Casing protection degree: IP20 (EN 60529) receivers, Protection level: II easy installation and service, Overvoltage category: II integration with wired home automation Pollution degree: 2 systems, cooperation with an unlimited number of Surge voltage: 1 kV (EN 61000-4-5) EXTA FREE system receivers, Dimensions: doublemodular casing (35 mm) 90 x 35 x 66 mm energy-saving device, used to constant Weight: 0,087 kg operation, Reference standard: ETSI EN 300 220-1, ETSI EN 300 220-2, connection possibility of antenna ANT-01 EN 60950, EN 61000 not mounted in a distribution board. APPEARANCE The device is designed for single-phase installation and must be installed in accord- Input (supply) terminals (L, N) ance with standards valid in a particular country. The de- vice should be connected ac- Antenna CAuTIoN cording to the details included in this operating manual. Installation, connec- tion and control should be carried out by a quali- Optic signalling of input voltage fied electrician staff, who act in accordance with the service manual and the device functions. Optic signalling of radio transmission In case of casing dismantling an electric shock may occur, and the guarantee is lost then. Antennas socket Before installation make sure the connection cables are not under voltage. The cruciform head screwdriver 3,5 mm should be used to Optic signalling of release (IN1, IN2, IN3, IN4) instal the device. Improper transport, storage, and use of the device influence its wrong func - tioning. It is not advisable to instal the device in the following cases: if any device part is missing Release terminals (IN1, IN2, IN3, IN4) or the device is damaged or deformed. In case of improper functioning of the device contact the producer. Additional Input (supply) terminals (L, N) The symbol means selective collecting of electrical and electronic equipment. It is forbidden to put the used equipment together with other waste. VER. 003 20.05.2011CoNNECTIoN FuNCTIoNING, MouNTING 1. Disconnect power supply by the phase fuse, the circuit-breaker or the switch-dis- connector combined to the proper circuit. 2. Check if there is no voltage on con- nection cables by means of a special measure equipment. 3. Connect the cables with the terminals in accordance with the installing diagram. 4. Mount RNM-10 device on a TH-35 rail. 5. Switch on the power supply from the mains. The device is ready to operate after proper mounting and installation. Device release by a unipolar push-button con- nected to one out of four release push- buttons (IN1-IN4) causes the RNM-10 de- vice to send a control signal which refers to this output (channel). LED red diodes IN1 - IN4 inform which channel was re- leased and the STATUS diode informs about transmission in progress. Device programming procedure (adding a transmitter to a receivers CAuTIoN: power supply memory) is described in particu- must be connected to lar receivers manual instruction of L i N terminals EXTA FREE system. APPLICATIoN oPERATING RANGE Receiver RNM-10 RoP-01 230 m RoP-02 250 m RoB-01 250 m SRP-02 250 m SRP-03 250 m RWG-01 300 m RWL-01 200 m RoM-01 300 m RoM-10 300 m RDP-01 230 m RTN-01 300 m CAuTIoN: The given range concerns open area - an ideal condition without any natural or artificial obstacles. If there are some obstacles between a transmitter and a receiver, it is advisable to decrease the range according to: wood and plaster: from 5 to 20 % bricks: from 10 to 40 % 4-channel radio modular transmitter RNM-10 reinforced concrete: from 40 to 80 % can control any EXTA FREE receiver. In this metal: from 90 to 100% application RNM-10 is released by a signal glass: from 10 to 20 % over- and underground medium and high from WZS-01 twilight switch, it sends a con- The ZAMEL company devices electrical power lines, radio and television trol signal to ROP-01 receiver, which switches which are characterised transmitters, GSM transmitters set close to on external lighting. with this sign can cooperate a device system have also a negative with each other. influence on the range. WARRANTY CARD There is 24 months guarantee on the product 1. ZAMEL provides a two-year warranty for its products. 2. The ZAMEL warranty does not cover: a) mechanical defects resulting from transport, loading / unloading or other circumstances b) defects resulting from incorrect installation or operation of ZAMEL products c) defects resulting from any changes made by CUS- TOMERS or third parties, to products sold or equipment necessary for the correct operation of products sold d) defects resulting from force majeure or other aleatory events for which ZAMEL is not liable e) power supply (batteries) to be equipped with a device in the moment of sale (if they appear) 3. All complaints in relation to the warranty must be provided by the CUSTOMER in writing to the retailer after discovering a defect. 4. ZAMEL will review complaints in accordance with existing regulations. 5. The way a complaint is settled, e.g. replacement of the product, repair or refund, is left to the discretion of ZAMEL. 6. Guarantee does not exclude, does not limit, nor does it suspend the rights of the PURCHASER resulting from the discrepancy between the goods and the contract. Salesman stamp and signature, date of sale